Rockwell Automation 1336F Plus II Parameters User Manual

Page 4

Advertising
background image

Par #

Parameter Name

Factory Default

Programmed Value

Par #

Parameter Name

Factory Default

Programmed Value

117

Data In D1

Read and Write

175

CR3 Out Select

Fault

118

Data In D2

Read and Write

176

CR4 Out Select

Alarm

119

Data Out A1

Read and Write

177

Motor NP RPM

1750 RPM

120

Data Out A2

Read and Write

178

Motor NP Hertz

60 Hz

121

Data Out B1

Read and Write

179

Local Owner

Read Only

122

Data Out B2

Read and Write

180

Process 2 Par

54

123

Data Out C1

Read and Write

181

Process 2 Scale

+1.00

124

Data Out C2

Read and Write

182

Process 2 Txt 1

Amps

125

Data Out D1

Read and Write

183

Process 2 Txt 2

Amps

126

Data Out D2

Read and Write

184

Process 2 Txt 3

Amps

127

Process 1 Par

1

185

Process 2 Txt 4

Amps

128

Process 1 Scale

+1.00

186

Process 2 Txt 5

Amps

129

Process 1 Txt 1

Volts

187

Process 2 Txt 6

Amps

130

Process 1 Txt 2

Volts

188

Process 2 Txt 7

Amps

131

Process 1 Txt 3

Volts

189

Process 2 Txt 8

Amps

132

Process 1 Txt 4

Volts

190

Motor NP Volts

Drive Rated Volts

133

Process 1 Txt 5

Volts

191

Motor NP Amps

Drive Rated Amps

134

Process 1 Txt 6

Volts

192

Flux Amps Ref

0.0 Amps

135

Process 1 Txt 7

Volts

193

KP Amps

100

136

Process 1 Txt 8

Volts

194

IR Drop Volts

Based on Drive Size & Type

137

MOP Freq

Read Only

195

Slip Comp Gain

1

138

Anlg In 0 Freq

Read Only

196

KP Volts

139

Anlg In 1 Freq

Read Only

197

Prod/Cnsu Error

140

Anlg In 2 Freq

Read Only

198

Rated VT Amps

Read Only

141

Motor Mode

Read Only

199

Rated VT kW

Read Only

142

Power Mode

Read Only

200

Flux Up Time

0.0 Sec

143

Flt Motor Mode

Read Only

201

Motor OL Fault

Enabled

144

Flt Power Mode

Read Only

202

Motor OL Count

Read Only

145

Fault Frequency

Read Only

203

VT Scaling

Disabled

146

Fault Status 1

204

Ground Warning

Disabled

147

Rated Volts

Read Only

205

Latched Alarms 1

148

Rated CT Amps

Read Only

206

Alarm Mask 1

1111111111111111

149

Rated CT kW

Read Only

207

Fault Data

Read and Write

150

4-20mA Loss Sel

Min/Alarm

208

Time Data 1

151

Maximum Speed

400 Hz

209

Time Data 3

152

Encoder Type

Quadrature

210

Time Data 5

153

Motor Poles

Read Only

211

Time Data 7

154

Anlg Out 0 Offst

Disabled

212

DC Bus Memory

Read Only

155

Flying Start En

Disabled

213

PI Config

00000000

156

FStart Forward

60 Hz

214

PI Status

Read Only

157

FStart Reverse

0 Hz

215

PI Ref Select

Preset 1

158

CR1 Out Select

At Speed

216

PI Fdbk Select

Analog In 1

159

Dig Out Freq

0.00 Hz

217

PI Reference

Read Only

160

Dig Out Current

0%

218

PI Feedback

Read Only

161

Dig Out Torque

0.0 Amps

219

PI Error

Read Only

162

Torque Current

Read Only

220

PI Output

Read Only

163

Flux Current

Read Only

221

KI Process

128

164

Speed KP

0

222

KP Process

256

165

Speed KI

100

223

PI Neg Limit

-8.33% of [Maximum Freq]

166

Speed Error

Read Only

224

PI Pos Limit

+8.33% of [Maximum Freq]

167

Speed Integral

Read Only

225

PI Preload

0.00 Hz

168

Speed Adder

Read Only

226

Shear Pin Fault

Disabled

169

Boost Slope

1.5

227

Adaptive I Lim

Enabled

170

Rated Amps

Read Only

228

LLoss Restart

Track Volts

171

Rated kW

Read Only

229

Freq Ref SqRoot

Disabled

172

EEPROM Cksum

Read Only

230

Save MOP Ref

Disabled

173

Fault Alarms 1

231

Hold Level Sel

DC Hold Lvl

174

CR2 Out Select

Running

232

Current Lmt Sel

Current Lmt