Environment, Protection features – Rockwell Automation 1606-XLP50E Power Supply Reference Manual User Manual

Page 12

Advertising
background image

All parameters are specified at 24V, 2.1A, 230Vac input, 25ªC ambient and after a 5 minutes run-in time unless noted otherwise.

12

Rockwell Automation Publication 1606-RM034A-EN-P — March 2014

Bulletin 1606 Switched Mode Power Supplies

17. Environment

Operational temperature

-10°C to +70°C (14°F to 158°F) Reduce output power according to Fig. 17-1

e

e

s

,

)

F

°

8

5

1

o

t

F

°

0

4

1

(

C

°

0

7

-

0

6

C

°

/

W

3

.

1

g

n

i

t

a

r

-

e

d

t

u

p

t

u

O

Fig. 17-1

Storage temperature

-40 to +85°C (-40°F to 185°F) Storage and transportation

0

3

-

2

-

8

6

0

0

6

C

E

I

.

H

.

r

%

5

9

o

t

5

y

t

i

d

i

m

u

H

Do not energize while condensation is present

Vibration sinusoidal 2-17.8Hz: ±1.6mm; 17.8-500Hz: 2g

2 hours / axis

IEC 60068-2-6

s

m

1

1

g

0

1

,

s

m

6

g

0

2

k

c

o

h

S

3 bumps / direction, 18 bumps in total

IEC 60068-2-27

t

n

e

i

b

m

a

r

o

r

e

w

o

p

t

u

p

t

u

o

e

c

u

d

e

R

)

t

f

0

0

0

0

2

o

t

0

(

m

0

0

0

6

o

t

0

e

d

u

t

i

t

l

A

temperature above 2000m sea level.

Output de-rating (for altitude)

3W/1000m or 5°C/1000m Above 2000m (6500ft), see Fig 17-2

0

5

N

E

I

I

I

y

r

o

g

e

t

a

c

e

g

a

t

l

o

v

-

r

e

v

O

178, IEC 62103 al titudes < 2000m

m

0

0

0

6

o

t

m

0

0

0

2

m

o

r

f

s

e

d

u

t

i

t

l

A

I

I

e

v

i

t

c

u

d

n

o

c

n

o

n

,

3

0

1

2

6

C

E

I

,

8

7

1

0

5

N

E

2

n

o

i

t

u

l

l

o

p

f

o

e

e

r

g

e

D

Fig. 17-1 Output current vs. ambient temp.

Fig. 17-2 Output current vs. altitude, 24V

0

-10

0

20

40

70° C

0.4

0.8

1.2

1.6

2.0

2.4A

60

Ambient Temperature

Allowable Output

Current at 24V

0

0

2000

4000

6000m

0.4

0.8

1.2

1.6

2.0

2.4A

Altitude

A ... Tamb < 60°C

B... Tamb < 50°C
C... Tamb < 40°C

A

B

C

Allowable Output

Current at 24V

The ambient temperature is defined 2cm below the unit.

18. Protection Features

Output protection Electronically protected against overload, no-load and short-circuits.
Output over-voltage protection

typ. 36V

max. 39V

In case of an internal power supply fault, a redundant
circuit limits the maximum output voltage. The output
shuts down and automatically attempts to restart.

Output over-current protection electronically limited see Fig. 10-1

Degree of protection

IP 20 EN/IEC 60529

Penetration protection

> 2.5mm in diameter E.g. screws, small parts

Over-temperature protection

not included

Input transient protection

MOV Metal Oxide Varistor

Internal input fuse

T3.15A H.B.C. Not user replaceable

Note: In case of a over-voltage, overload, no-load or short-circuit event, an audible noise may be heard.

Advertising