All parameters are specified at 24V, 2.1A, 230Vac input, 25ªC ambient and after a 5 minutes run-in time unless noted otherwise.

Rockwell Automation Publication 1606-RM034A-EN-P — March 2014

7

Bulletin 1606 Switched Mode Power Supplies

10. Output

Output

voltage

nom.

24V

Adjustment

range

min.

24-28V Guaranteed

max.

30V

At clockwise end position of potentiometer

Factory

setting

24.5V

±0.2%,

at full load, cold unit

Line

regulation

max.

10mV 85

to

264Vac

Load

regulation

max.

100mV Static

value,

0A

2.1A

0A

Ripple and noise voltage

max.

50mVpp 20Hz

to

20MHz,

50Ohm

Output

capacitance

typ.

1600μF

Output current

nom.

2.1A

At 24V, see

Fig. 10-1

nom.

1.8A

At 28V, see

Fig. 10-1

Output

power

nom.

50W

Short-circuit

current

min.

3.1A

Load impedance 400mOhm, see

Fig. 10-1

max.

5A Load impedance 400mOhm, see

Fig. 10-1

Fig. 10-1 Output voltage vs. output current,

230Vac, typ.

Output Voltage

0

0

1

2

4

8

12

28V

16

20

24

4A

2.5

1.5

0.5

3

3.5

Adjustment

Range

Output Current

Peak current capability (up to several ms)
The power supply can deliver a peak current which is higher than the specified short term current. This helps to start
current demanding loads or to safely operate subsequent circuit breakers.
The extra current is supplied by the output capacitors inside the power supply. During this event, the capacitors will
be discharged and cause a voltage dip on the output. Detailed curves can be found in section 27.1.

Peak current voltage dips

typ.

from 24V to 16V

at 4.2A for 50ms, resistive load

typ.

from 24V to 15V

at 10.5A for 2ms, resistive load

typ.

from 24V to 10.5V

at 10.5A for 5ms, resistive load