Data Formats

Appendix A

A–2

The digit in the response/error code labeled “Y” will adhere to the
following definitions:

b7

b6

b5

b4

channel

4 rate

overrange

channel

3 rate

overrange

channel

2 rate

overrange

channel

1 rate

overrange

“1” indicates overrange

“0” indicates not overrange

Note that the overrange condition causes both the rate and total to be
zeroed

The digit in the response/error code labeled “X” will adhere to the
following definitions:

b11

b10

b9

b8

channel

4 total

overflow

flag

channel

3 total

overflow

flag

channel

2 total

overflow

flag

channel

1 total

overflow

flag

“1” indicates totalizer has overflowed

“0” indicates totalizer has not overflowed

Important: When the totalizer overflows, it continues to count unless
manually reset.