3–6

Setting Up the Software

Publication 1746-6.18 April 1998

LDT

head

For Position Data Increasing Towards LDT Head (Ge:0/15 = 1)

Position

V5

V6

V7

Voltage

Output = 0
past position 1

V2

V3

V4

V1

P7

P6

P5

P4

P3

P2

P1

Speed
Segment 6

Speed
Segment 5

Speed
Segment 4

Speed
Segment 3

Speed
Segment 2

Speed
Segment 1

Starting with the ram between P7 and the LDT head (open position),
running the extend profile results in V7 applied to the output.
As the ram passes below P7, V6 is applied to the output, etc.

If the ram passes below P1, the output is forced to 0V dc, and the
profile is disabled. You must load new data to operate the profile.

Placement operations require two segments.
For example, if P2 = 6.07”, V2 = 1.500V, P1 = 0.00” (or a value
less than P2), and V1 = –1.500V, then the module will place the
ram in the vicinity of P2 (between 6.02 and 6.12). The negative
voltage V1 causes motion to reverse or stop. To see this, enter the
example values for P2, V2, P1, and V1 in the previous diagram.

Position

V3

V2

V1

Voltage

LDT

head

Output = 0
past position 7

Position Data Increases from LDT Head (Ge:0/15 = 0)

V6

V5

V4

V7

P4

P5

P7

Speed
Segment 6

Speed
Segment 5

Speed
Segment 4

Speed
Segment 3

Speed
Segment 2

Speed
Segment 1

P1

P2

P3

P6

Starting with the ram between P1 and the LDT head (open position),
running the extend profile results in V1 applied to the output.
As the ram passes P1 towards P2, V2 is applied to the output, etc.

If the ram passes P7, the output is forced to 0V dc, and the extend
profile is disabled. You must load new data to operate the profile.