Getting ready to tune the axes, Tuning each axis, Getting ready to tune the axes tuning each axis – Rockwell Automation 1746-QS,D17466.19 SYNCHRONIZED AXES MODULE User Manual

Page 21

Advertising
background image

4–5

Publication 1746-6.19 March 1998

Once you have set scale, offset, and extend/retract limits in open-loop
mode, you can now use the Hydraulic Configurator to tune the axis
using closed-loop move commands and axis plots. We suggest that you:

1. Leave un-entered configurations parameters at default, except for:

– Auto Stop to 000E0 (hard stop, only for LDT faults)

2. If not done already, initialize the axes with the “P” command.

3. Store two 6-word motion commands in the Stored Command Editor:

– Mode word = 00000
(This sets integrator to Always Active and accel/decel to slow ramp.)

SPEED, ACCEL

, and

DECEL

values at 20% of typical machine move

(For safety, start slow and increase

SPEED

gradually.)

COMMAND VALUE

s to desired end positions for the axis to tune

– Zero all six command words of the axes not to be tuned

4. Set the plot clock (in even-numbered seconds, 20 max) to longer

than you expect for the axis to run “tuning” moves.

5. ATTENTION: Highlight the axis you want to move before moving

the axis back and forth using stored commands

[1]

and

[2]

.

Unexpected motion could occur if the wrong axis is highlighted.

6. Open the status bits window (Ctrl-B), and check the

STATUS

word

for errors while the axis is moving.

7. View captured axis plots (click [

] in the ToolBar).

Observe the Sum-Error

2

value displayed in the window.

‘There is no substitute for experience when tuning an axis. This
section offers some guidelines, tips, and suggestions for tuning your
system. While helpful for many systems, they may not be the best
for a particular system. We help you with:

General Procedure for Tuning an Axis

Adjusting Command-word Speed and Acceleration values

Adjusting Feedforward Parameters

Using Acceleration Feedforwards

Adjusting PID Gains

General Procedure for Tuning an Axis

Use this generalized procedure with the Hydraulic Configurator.

Move the axis using stored commands

[1]

and

[2]

.

Observe the axis plot for each move.

Adjust one configuration parameter at a time in the order given.

1. Observe plots of axis moves between the two positions that you

set up with stored commands in the previous section, Getting
Ready. Observe following error, overshoots, and oscillations.

For adjusting command values and configuration parameters, refer to
Adjusting Command-word Speed and Acceleration Values, page 4-7.

Getting Ready to
Tune the Axes

Tuning Each Axis

Advertising