Wire the module – Rockwell Automation 1734-OW2_OW4, Series C Point I/O 2 and 4 Relay Output Modules User Manual
Page 14
14 POINT I/O 2 and 4 Relay Output Modules
Publication 1734-IN055F-EN-E - March 2012
Wire the Module
Relay contacts are not directly powered by the internal power bus. Load power from the
internal power bus is available for the 1734-OW2 only. Connect to pins 6 and 7 for
V supply, and to pins 4 and 5 for V common.
WARNING: If you connect or disconnect wiring while the field-side power is
on, an electrical arc can occur. This could cause an explosion in hazardous
location installations. Be sure that power is removed or the area is
nonhazardous before proceeding.
Relay
Output
Module
Status
Network
Status
1734
OW4
NODE:
0
1
2
3
Relay
Output
Module
Status
Network
Status
1734
OW2
NODE:
0
1
Module status
Network status
Status of output 0
Status of output 1
C
V
C
V
C = Common
V = Supply
Output 0A
Output 0B
Output 1A
Output 1B
Status of output 2
Status of output 3
Output 0A
Output 0B
Output 1A
Output 1B
Output 2A
Output 2B
Output 3A
Output 3B
45183
45184
1734-OW2
1734-OW4