16 ArmorPOINT I/O 5V DC Encoder/Counter Module, Series A

General Specifications (continued)

Vibration

IEC60068-2-6 (Test Fc, Operating):

5g @ 10...500Hz

ESD Immunity

IEC 61000-4-2:

6kV contact discharge

8kV air discharge

Radiated RF Immunity

IEC 61000-4-3:

10V/m with 1kHz sine-wave 80% AM from 80...2700 MHz

10V/m with 200Hz 50% Pulse 100% AM from 900...1890 Mhz

EFT/B Immunity

IEC 61000-4-4:

±2 kV @ 5.0 kHz on signal ports

Surge Transient Immunity

IEC 61000-4-5:

±1 kV line-line (DM) and ±2 kV line-earth (CM) on signal ports

Conducted RF Immunity

IEC 61000-4-6:

10V rms with 1 kHz sine-wave 80% AM from 150 kHz...80MHz

Emissions

CSPR 11:

Group 1, Class A

Enclosure Type Rating

Meets IP65/66/67 (when marked)

Mounting Base Screw Torque

#8 screw:

0.847 Nm – Aluminum

1.807 Nm – Steel

Weight (approx.)

0.289 kg

(0.637 lb.)

Wiring Category

1

2 - on signal ports

Certifications:

(when product is marked)

c-UL-us UL Listed Industrial Control Equipment, certified for US and Canada

CE

3

European Union 2004/108/EC EMC Directive, compliant with:

EN 61000-6-2; Industrial Immunity

EN 61000-6-4; Industrial Emissions

EN 61131-2; Programmable Controllers (Clause 8, Zone A & B)

EN 61326-1; Meas./Control/Lab., Industrial Requirements

C-Tick

3

Australian Radiocommunications Act, compliant with:

AS/NZS CISPR 11; Industrial Emissions

1. Use this Conductor Category information for planning conductor routing. Refer to Industrial Automation Wiring and Grounding

Guidelines, publication

1770-IN041

, for additional installation requirements.

2. See the Product Certification link at

http://www.rockwellautomation.com/products/certification/

for Declarations of Conformity,

Certificates, and other certification details.