Interpreting the status indicators – Rockwell Automation 1771-OND INSTL.INSTR AC (24V) OUTPT.MOD User Manual

Page 7

Advertising
background image

AC (24V) Output Module

7

Publication 1771Ć5.41 - May 1996

The front panel of your module contains one green, module active
indicator, and 16 red status indicators (Figure 4). The 1771-OND
performs diagnostics in a handshaking mode when first powered up.
Upon successful completion of the diagnostics, the green module
active indicator lights. It turns off if a fault occurs in the data paths
or the opto-isolators.

The red status indicators are provided for system logic side
indication of individual inputs. When a red indicator lights, voltage
is present on the terminal. The module transfers this information to
the backplane for the processor to read.

Figure 4

Status Indicators

ACTIVE

00

01

02

03

04

05

06

07

10

11

12

13

14

15

16

17

Module Active Indicator (green)

00 to 17 Status Indicators (red)

10676ĆI

Interpreting the Status

Indicators