MP-Series Low-inertia Servo Motor with 215 mm or Larger Frame Size 13

Rockwell Automation Publication MP-IN002D-EN-P - January

ATEX Installations

If your motor has an ATEX rating for hazardous environments, complete the following step. The
catalog number on ATEX motor nameplates ends with H, for example MPL-

xxxxx-xxxxH.

Verify the continuity and functionality of the thermal switch signals, TS+ and TS-, transmitted
through the feedback cable that connects the motor to its controlling drive.

ATTENTION: It is mandatory that the motion system monitor the thermal switch signals from a motor
requiring an ATEX rating.

The intrinsic safety protection concepts in the ATEX Direction 94/9/EC must be enabled by connecting the
thermal switch signals from the motor to the motion control system.