TP10494A

Accept the displayed sheet length by pressing the

“ENTER” button. This will activate the single sheet

mode.

·

2.) Do nothing.

After 5 seconds, the count screen will be displayed.

10.2 Setting up a special fold.

This machine has 3 memory locations that can be

used to store special fold settings. These will store the plate

settings, the stacker wheel location, and the speed setting for

a fold.

10.2.1 To save a nonstandard fold in a memory

location.

Set up the fold as you normally would. Once the speed

and folds are set the way you want, press a “MEMORY

SET” button. Recall will appear in the display. Press the

(-) button to get to the STORAGE screen.

10.2.2 Recall a fold saved in memory location.

Press the “MEMORY SET” button that corresponds

to the memory location you wish to recall. RECALL will

appear. Press the ENTER button.

10.3 Starting Production:

After the sheet length and the fold type has been

selected, production is started by:

Starting the main drive (press “DRIVE”),

·

Start the pneumatic pump (press “PUMP”) and

·

TOTAL COUNT #######

BATCH ### #####