Baumfolder Flexifold: 1st Station (from 2005) User Manual
Page 30
PAGE 30
TP10494A
Accept the displayed sheet length by pressing the
“ENTER” button. This will activate the single sheet
mode.
·
2.) Do nothing.
After 5 seconds, the count screen will be displayed.
10.2 Setting up a special fold.
This machine has 3 memory locations that can be
used to store special fold settings. These will store the plate
settings, the stacker wheel location, and the speed setting for
a fold.
10.2.1 To save a nonstandard fold in a memory
location.
Set up the fold as you normally would. Once the speed
and folds are set the way you want, press a “MEMORY
SET” button. Recall will appear in the display. Press the
(-) button to get to the STORAGE screen.
10.2.2 Recall a fold saved in memory location.
Press the “MEMORY SET” button that corresponds
to the memory location you wish to recall. RECALL will
appear. Press the ENTER button.
10.3 Starting Production:
After the sheet length and the fold type has been
selected, production is started by:
Starting the main drive (press “DRIVE”),
·
Start the pneumatic pump (press “PUMP”) and
·
TOTAL COUNT #######
BATCH ### #####
RECALL
(N) - (Y) ENTER
RECALL
(N) - (Y) ENTER
STORAGE
(N) - (Y) ENTER