Passive Calibration

Calibrate the TPM on the transmitter it is monitoring. Also a refer-

ence power meter is needed to measure the output of the test port on

the TPM (model 7006A250). This calibration can be performed while

transmitting on air (forward only) or into a dummy load. Coupling

calibration data for the TPM is also needed.
By using several different power levels, an equation or lookup table

can be generated for the voltage output of the TPM as a function of

power level at the frequency of calibration.
1. Install the TPM to the transmission line. Refer to “Installing the

TPM” on page 4.

2. Remove the load from the Fwd testport.
3. Connect the calibration standard to the Fwd testport.
4. Apply RF power.
5. Record the transmitter frequency displayed and find the listing

closest to it on the TPM’s coupling calibration data card.

Note:

Make note of the calibration factor.

6. Enter the calibration factor into the calibration standard’s offset

function.

7. Measure the power on the calibration standard and voltage on the

TPM output simultaneously.

8. Record the voltage verses power.
9. Turn the unit around and repeat steps 1 to 7 for Reflected calibration.

Note:

Reflected fullscale is 1/10th of forward fullscale.

Note:

Calibrating the reflected port is often optional.

Check with the FCC or other ruling body to determine if it is
necessary or not.

Figure 6

Forward Calibration Set-Up

TPM

Connector

Figure 7

Reflected Calibration Set-Up

Calibration Standard

Figure 5

Calibration Kit