Troubleshooting – Bird Technologies 3140 Display User Manual
Page 31
Maintenance
21
Troubleshooting
The TPM has no operator serviceable parts. Any required service must
be performed at an authorized service facility.
The table below contains troubleshooting information for problems
which can occur during normal operation. This manual cannot list all
malfunctions that may occur or their corrective actions. If a problem is
not listed or is not corrected by the listed actions, notify a qualified
service center.
Transmitter Power Monitor
Problem
Possible Cause
Correction
Power LED does
not illuminate
No dc power
Check power
source, and cable
Defective LED
Return the unit to
an authorized
service center
High VSWR
Dirty connectors
Clean connectors
Defective
connectors
Replace connectors
Shorted or open
transmission line
Have the line
serviced.
3140 Panel
Problem
Possible Cause
Correction
Display does not
light
Unit is not turned on
Set AC Power
Switch to ON
Unit is not plugged
in
Connect ac power
cord