10

Note: Connections are the same for the Bird 5011 and 5011-EF.

1.

Do one of the following:

Connect the DPM port on the Bird TPS to the “Sensor” serial port on
the DPM using the sensor cable provided.

Connect the DPM port on the Bird TPS to the “Sensor” USB port on the
DPM using the sensor cable provided.

Note: An attenuator or directional coupler should be used with the
TPS in most applications.
Example - For an RF source with output between 0.1 and

50 W, use a 40 dB, 50 W attenuator.

2.

Connect the TPS RF input to the source (using an attenuator, if appropriate).

Note: Only connect the TPS directly to a source if the RF power will
be less than 10 mW.

Resetting the 5000-XT

Pressing and holding down the 5 button for two seconds will reset the unit.

The unit will return to default settings and pop-up the language selection menu.

Upgrading the Firmware

Note: Before performing this procedure, sign on to the internet and
go to:
www.bird-technologies.com/products/software/5000-xt/

1.

Power on the 5000-XT

2.

Connect the USB from the 5000-XT to the PC and wait for the drive to appear.

Note: This could take 30 seconds

3.

Create a folder named “FIRMWARE”.

Note: The folder name is case sensitive. If there is already a folder,
use the existing folder, but delete any firmware versions already in
that folder.

4.

Place the updated firmware file into the folder.

Note: This file can be named anything as long as the file extension is
.bin.

CAUTION

Do not exceed 2 W average or 125 W peak power for 5 μs when using the TPS

or the TPS-EF. Doing so will render the sensor inoperative.