Bird Technologies 4331 User Manual

Page 34

Advertising
background image

The Model 43 is normally supplied with two Female N type connectors which

are of the Bird Quick-Change design. Other “QC” connectors are available,

refer to the Replacement Parts List in the Maintenance Chapter.
Follow these steps to change the “QC” connectors.

1. Remove the four 8-32 pan head machine screws from the

corners of the connector flange.

2. Pull the connector straight out.
3. Reverse this procedure to attach connector, making sure

the center contact pin aligns properly with the socket.

Remote Installation

The RF line section can be removed from the meter housing for remote

installation. To remove the line section from its housing:

1. Unscrew the four 8-32 flat head machine screws holding

the back cover.

2. Grasp the cover by the side filler tabs and pull directly

backwards. The back cover assembly will come off with

the speed nuts remaining attached.

3. Remove the two 10-32 oval head machine screws on the

front of the housing.

4. Slide the line section backwards out of the housing. Do not

loosen the two oval head screws on the sides of the hous-

ing in line with the meter. These hold the meter support-

ing shock ring in place.

5. Substitute the cable which attaches the line section to the

meter with a sufficient length of cable to make the re-

mote installation.

6. To replace the RF line section, reverse the above listed pro-

cedures.

It may be desirable to have two or more line sections permanently installed

in continuous operating equipment. In this case, one set of elements and one

Bird Model 43 Wattmeter

20

Advertising
This manual is related to the following products: