Bird Technologies 4331 User Manual

Page 53

Advertising
background image

Maximum

Counterclockwise

Frequency (MHz)

Sensitivity
(Fully Clockwise)

4 Full Turns
From Max.
Position

7 Full Turns
From Max.
Position

2

69

(Approximate dB
attenuation)

(Approximate dB
attenuation)

10

57

25

46

50

42

75

39

100

36

200

31

300

38

400

34

500

30

600

29.5

700

29

800

28.5

36

900

28

35.5

1000

35

Note: It is important to decouple the RF sampler as indicated above for

frequencies above 200 MHz. The basic specifications of this instrument will

be maintained with the above settings for the RF sampler. Decouple or turn

counterclockwise beyond the above settings as much as possible, when

possible.

Table 1

Model 4431 Coupling Data

Maintenance

39

Advertising