To apply a DFL patch and modify some parameters in the battery firmware, just select the desired patch from the table
and click the "APPLY TO BATTERY" button:
the battery is temporarily halted when the new data is being uploaded (it may take up to 20 seconds), and must not be
disconnected during this time.
At the end of this operation may be necessary to reset the battery to allow the modified settings to take effect.

CBA control

The CBA control frame allows the control the CBA unit. By operating this control, a load will be instantly set to discharge
the battery.

The CBA control is enabled only when a

READ

session is started and is disabled when the session is stopped.

It consists of:

a slider, to selected and vary the load

a stop button

an option button to switch the load scale between Ampere an Watt

a display to show the selected load

The slider moves between zero and the max load, tipically 10000mA or 150W: on moving the slider, the display is updated
but the load starts only when the mouse button is released.

The red LED on the CBA unit lights on to indicate that the discharge session started, and the fan embedded in the CBA
unit start to spin silently.

The discharge current is software and electronically regulated using a solid state switch and fan cooled electronic load,
and it is automatically kept constant during the whole test. If the option button is changed between Ampere and Watt, the
actual load is converted and shown and the slider scale is changed. However, the load applied to the battery is not
affected.

The load can be cleared and the discharge interrupted in three possible ways: