by the user, when pressing the stop button in the control frame: the read session continues, but the load is cleared

by the user, when pressing the

STOP button

to terminate the read session

by the system, when the minimum battery voltage is reached or when an automatic temperature, current or power
protection occur in the CBA unit

Connection status

The bottom border of the main form shows the actual connection status.

Left side: BSMon status

this section provides information about the status of the communication between PC and BSMon:

when the communication is active, a green mark will appear citing number 0 in square brackets

If the communication is not good, a red mark will notify it, and a related error message and number will explain the

reason.

The following are the most probable error conditions:

means that during start-up of BSMon, the USB device had not been detected by the PC

means that the PC could not detect the USB device (BSMon) properly

means that the USB device (BSMon) is no longer responding to the PC

means that the battery is not responding or not properly connected to the USB device (BSMon)

Right side: CBA status

a red mark means that the CBA Unit is disconnected and not communicating

a green mark means that CBA load is connected properly. In this case, additional status information are provided in

bracket:

0: the unit is idle

1: the load is working, a test is running

2: the test terminated naturally, the battery low voltage limit has been reached

3: the test halted because the CBA unit overheated