4: the test halted because terminated by the user or by other event (i.e. sudden battery cut-off)

5: the unit is executing a command and is temporarily unavailable

To understand how to connect the battery, please refer to the

Installation

section.

To troubleshoot connection problem, refer to the

Troubleshooting

section.

Troubleshooting

In this section:

Battery problems

explains how to work around battery related problems.

Communication problems

explains how to work around the most common communication problems.

Battery problems

Battery problems have to be evaluated depending on their specific characteristics.

The battery does not accept any charge.

This means that a charge safety protection has been activated, and the related MOSFET should be turned OFF.

Several reasons could justify this:

Overvoltage

Overtemperature

Undertemperature

Charge Overcurrent

The battery does not allow any discharge.

This means that a discharge safety protection has been activated, and the related MOSFET should be turned OFF..

Several reasons could justify this:

Undervoltage

Overtemperature