90 appendices, Exclusice communication, Parameter address map – Boss Audio Systems GS-10 User Manual

Page 90: One way communication, Midi machine control (mmc), Request data 1 rq1(11h), Data set 1 dt1(12h), Inquiry message

Advertising
background image

90

Appendices

MIDI Machine Control (MMC)

F0H 7FH 7FH 06H com F7H

F0H =

System Exclusive

7FH =

ID Number (Universal Realtime Message)

7FH =

Device ID (Broadcast)

06H =

Sub ID#1(Machine Control Command)

com =

Sub ID#2(MMC Command)

F7H =

EOX (End of Exclusive/System common)

*

“com” (MMC Command) that I transmit with GS-10 is following.

01H

Stop

02H

Play

44H 06H 01H 00H 00H 00H 00H 00H

RESET

06H

REC

3. EXCLUSICE COMMUNICATION

On the GS-10, exclusive messages can be used as follows. - Transmit/receive GS-10 system/
patch data.
The model ID for GS-10 exclusive messages is 00H 63H, and you can set up the device ID at
00H–1FH.

ONE WAY COMMUNICATION

Request Data 1

RQ1(11H)

F0H 41H dev 00H 63H 11H aaH bbH ccH ddH ssH ttH uuH vvH sum F7H

F0H =

Exclusive Status

41H =

Manufacturer ID

(Roland)

dev =

Device ID

(Dev=00H-1FH)

00H =

Model ID

MSB (GS-10)

63H =

Model ID

LSB (GS-10)

11H =

Command ID

(RQ1)

aaH =

Address

MSB

bbH =

Address

:

ccH =

Address

:

ddH =

Address

LSB

ssH =

Size

MSB

ttH =

Size

:

uuH =

Size

:

vvH =

Size

LSB

sum =

Checksum

F7H =

EOX

(End of System Exclusive)

*

This message can only be received, and is not transmitted from the GS-10.

*

When transmitting large Size values spanning fragmented addresses, the data can be
transmitted only to those addresses that are contiguous.

Data Set 1

DT1(12H)

F0H 41H dev 00H 63H 12H aaH bbH ccH ddH eeH ... ffH sum F7H

F0H =

Exclusive Status

41H =

Manufacturer ID

(Roland)

dev =

Device ID

(dev = 00H-1FH)

00H =

Model ID

MSB (GS-10)

63H =

Model ID

LSB (GS-10)

12H =

Command ID

(DT1)

aaH =

Address

MSB

bbH =

Address

:

ccH =

Address

:

ddH =

Address

LSB

eeH =

Data

: =

:

ffH =

Data

sum =

Checksum

F7H =

EOX

(End of System Exclusive)

*

When transmitting large amounts of data spanning fragmented addresses, the data can
be transmitted only to those addresses that are contiguous.

Inquiry Message

Identity Request

F0H 7EH 10H 06H 01H F7H

F0H =

Exclusive Status

7EH =

ID Number

10H =

Device ID

06H =

Sub ID#1

01H =

Sub ID#2

F7H =

EOX (End of System Exclusive)

*

The 7FH (Broadcast) device ID is also supported.

*

When an Identity Request is received, the GS-10 will transmitted the following Identity
Reply.

Identity Reply

F0H 7EH 10H 06H 02H 41H 63H 01H 00H 00H 00H 00H 00H 00H F7H

F0H= Exclusive

Status

7EH=

ID Number (Universal Non-realtime Message)

10H= Device

ID

06H= Sub

ID#1

02H= Sub

ID#2

41H= ID

Number

(Roland)

63H 01H=

Device Family Code

00H 00H=

Device Family Number Code

00H 00H 00H 00H= Software Revision Level
F7H=

EOX (End of System Exclusive)

*

When an Identity Request is received, the GS-10 will transmitted the following Identity
Reply.

4. PARAMETER ADDRESS MAP

The address and size are displayed under 7-bit hexadecimal notation.

Address

MSB

LSB

Binary

0aaa aaaa

0bbb bbbb

0ccc cccc

0ddd dddd

7-bit Hexadecimal

AA

BB

CC

DD

Size

MSB

LSB

Binary

0sss ssss

0ttt tttt

0uuu uuuu

0vvv vvvv

7-bit Hexadecimal

SS

TT

UU

VV

Advertising