Pc-2200 – Bowers Group Advanced Electronic/Air Column PC-2200 User Manual

Page 19

Advertising
background image

PC-2200

BOWERS METROLOGY page 19 /32 version 2.06 -E



3.1 LAYOUT OF IN/OUTPUT


























Circuit connection diagram (OUTPUT)

CH-Bus diagram









Pin#

Functions

1

* (not connected)

2 Rxd
3 Txd
4 Vcc
5 Gnd
6

* (not connected)

7 Rts
8 Cts
9 Gnd

Pin#

Functions

1

RS 232 sortie (0.5 sec.)

2

Current value display

3 Dynamic/Static
4 M1->M2->M3->M4
5 Hold

measure

6

* (not connected)

7

* (not connected)

8

* (not connected)

9 Gnd

Pin#

Functions

Class Mode
(Binary)

1

O.K (Green)

Bit 0

2

* (not connected)

Bit 1

3

Approch + (Orange)

Bit 2

4

+N.G (Red)

Bit 3

5

* (not connected)

Bit 4

6

Approch – (Orange)

Bit 5

7

-N.G (Red)

Bit 6

8

Drive Voltage

9 Gnd

Pin#

Functions

1 D/A

sortie

2

* (not connected)

3

* (not connected)

4

* (not connected)

5

* (not connected)

6

* (not connected)

7

* (not connected)

8

* (not connected)

9 Gnd

Pin#

Functions

1 Ex-A
2 Ex-B
3 Ex-C
4 Ex-D
5 Gnd
6

* (not connected)

7

* (not connected)

8

* (not connected)

9 Gnd

1

2
3

4
5

6

7
8

9

1

2
3

4
5

6

7
8

9

1
2

3
4

5

6
7

8
9

1

2
3

4
5

6

7
8

9

1

2
3

4
5

6

7
8

9

RS-232 C

EXT.CON

OUTPUT

DC OUT

CH-BUS

Analog board PCB

A B C D

A/E

-Converter

Display controller

EX-A (pin #1)
EX-B (pin #2)
EX-C (pin #3)
EX-D (pin #4)

Probe
input

(Connection of a serial printer or a PC)

In the case of RS232-RS mode is set as “PRINT”, the display value is printed via the RS232 by

connecting the pins #1,9 of external control..

If the RS 232-RS mode is set as « HOST », the communication becomes (duplex) and allows to

use the communicator software.

The external control functions can be activated by connecting the pins #1 to 5 to the pin
#9(GND) according to the required function.
The following functions can be activated by connecting the pin #9 to pin # (foot pedal, box)
#1)Print the display value. #2) Change dynamic mode to static mode
#3) Reset the dynamic mode (min., max.) #4) Move the measurement mode (M1) to M2,……
M2,M3,M4 should be active. (ON)
#5) Freeze the displayed value.
Active the preset mode by connecting the pin #3 and #5 simultaneously

Active the contact with GND pin#9 when the value of the bar is positioned in the

corresponding range pins #1, 3, 4, 6, 7) .

This application shows if the product is acceptable or not with an external unit

such as lamps, relays, by powering the pins #8,9.

If the Class mode is turned on, the judgement mode(OK, +/-NG, etc.) is

automatically turned off and the data is output with BCD code through the same

port(each pin).(Refer to the chapter 3.6 for setting up.)

Analog output of the display (Signal Voltage (pin #1 and #9).

The voltage range is : Approx. ±4.3V with ±1 mm, or ±0.05 inch

This function is used when the signal of a probe should be shifted to a second column.

Application : Example : Display a maximum value on 1 column and a minimum value to the other

column with only one probe..

The analog board of the column which is receiving the data should be disconnected,

.

Red

(bigger value than TOLER+)

Green

(Value between APPRO- and APPRO+)

Orange

(Value between APPRO- and TOLER-)

Red

(smaller value than TOLER-)

E=External voltage

Orange

(Value between APPRO+ and TOLER+)

GND

E

#7

#4

#6

#3
#1

#9

Advertising