Sync mode settings – Boss Audio Systems SP-505 User Manual

Page 72

Advertising
background image

72

Chapter 12. Using the SP-505 with other MIDI devices

Never turn off the power while the display indicates
“Keep Power On!”

The SP-505 transmits pad performance data as sets
consisting of “program change message + note
message.” If this performance data is overdubbed on an
external sequencer, some sequencers may automatically
rearrange the overdubbed data, making it impossible for
the performance data to be reproduced correctly.

Synchronizing the
performance of the SP-505
and an external MIDI device

In order for the performance to be synchronized with an
external MIDI device, you must decide which device (the SP-
505 or the external MIDI device) will control start/stop, and
which device will determine the BPM (Sync mode).

Connections for synchronized
performance

Use a MIDI cable to connect the MIDI OUT connector of the
master device to the MIDI IN connector of the SP-505.

fig.12-03

Sync mode settings

1. Press [SONG] or [PTN] to display the Play screen.

2. Press [SYSTEM] to display the System screen.

fig.10-01a

* It is not possible to display the System screen while a pattern

or song is playing.

3. Press [F1] (UTILITY).

4. Press [F2] (MIDI).

The MIDI Settings screen will appear.

5. Press CURSOR [

] to select Sync Mode, and use the

VALUE dial to change the setting.

fig.12-04

* If the Sync Mode is set to MIDI, playback will not occur

unless MIDI Clock messages are received from an external
MIDI device.

6. Press [PTN] or [SONG] to return to the Play screen.

Never turn off the power while the display indicates
“Keep Power On!”

* At the factory settings, this is set to AUTO.

* It is not possible to change the MIDI settings while the

sequencer is playing.

Master

Slave (SP-505)

MIDI IN

MIDI OUT

Start/Stop

BPM

INT

Control from SP-505
only

Use SP-505’s internal
BPM

MIDI

Control from SP-505/
Control from external
MIDI device

Use MIDI Clock
messages

REMOTE

Control from SP-505/
Control from external
MIDI device

Use SP-505’s internal
BPM

AUTO

Control from SP-505

Use SP-505’s internal
BPM

Control from external
MIDI device

Use MIDI Clock
messages

Advertising