85 chapter 15. appendices, Appendices, System common message – Boss Audio Systems SP-505 User Manual

Page 85: System realtime message, System exclusive message

Advertising
background image

85

Chapter 15. Appendices

6

Appendices

If the Pad Bank is the PITCH BANK (#15, 16), note numbers 23H (35) and 3CH-48H (60-72)
are transmitted.

Pad Number

Note Number

Pad 1

-- (--H)

Pad 2

61 (3DH)

Pad 3

63 (3FH)

Pad 4

-- (--H)

Pad 5

66 (42H)

Pad 6

68 (44H)

Pad 7

70 (46H)

Pad 8

-- (--H)

Pad 9

60 (3CH)

Pad 10

62 (3EH)

Pad 11

64 (40H)

Pad 12

65 (41H)

Pad 13

67 (43H)

Pad 14

69 (45H)

Pad 15

71 (47H)

Pad 16

72 (48H)

*

Not transmitted if the Pad Bank is the CHOP BANK (#13, 14).

Program Change

Transmit the message in the MIDI channel number which is designated with “Pads
Channel” or “Part1-4 Channel” in the system parameter “SYSTEM/UTILITY/MIDI”. After
the pad bank is switched, this is transmitted as a set together with note data.
This message is transmitted when the “Prog Chg SW” of the system parameter “SYSTEM/
UTILITY/MIDI” is set at ON.

Status

Second

CnH

ppH

n = MIDI Channel Number:

00H - 0FH (ch.1 - ch.16)

pp = Program Number:

00H - 1FH (pad bank 1 - 12, 15 - 32)

+—————+———————————————+—————+———————————————+
| PC# | PAD BANK | PC# | PAD BANK |
+—————+———————————————+—————+———————————————+
| 1 | PRESET BANK 1 | 17 | CARD BANK 1 |
+—————+———————————————+—————+———————————————+
| 2 | PRESET BANK 2 | 18 | CARD BANK 2 |
+—————+———————————————+—————+———————————————+
| 3 | PRESET BANK 3 | 19 | CARD BANK 3 |
+—————+———————————————+—————+———————————————+
| 4 | PRESET BANK 4 | 20 | CARD BANK 4 |
+—————+———————————————+—————+———————————————+
| 5 | USER BANK 1 | 21 | CARD BANK 5 |
+—————+———————————————+—————+———————————————+
| 6 | USER BANK 2 | 22 | CARD BANK 6 |
+—————+———————————————+—————+———————————————+
| 7 | USER BANK 3 | 23 | CARD BANK 7 |
+—————+———————————————+—————+———————————————+
| 8 | USER BANK 4 | 24 | CARD BANK 8 |
+—————+———————————————+—————+———————————————+
| 9 | USER BANK 5 | 25 | CARD BANK 9 |
+—————+———————————————+—————+———————————————+
| 10 | USER BANK 6 | 26 | CARD BANK 10 |
+—————+———————————————+—————+———————————————+
| 11 | USER BANK 7 | 27 | CARD BANK 11 |
+—————+———————————————+—————+———————————————+
| 12 | USER BANK 8 | 28 | CARD BANK 12 |
+—————+———————————————+—————+———————————————+
| —— | ——— | 29 | CARD BANK 13 |
+—————+———————————————+—————+———————————————+
| —— | ——— | 30 | CARD BANK 14 |
+—————+———————————————+—————+———————————————+
| 15 | PITCH BANK 1 | 31 | CARD BANK 15 |
+—————+———————————————+—————+———————————————+
| 16 | PITCH BANK 2 | 32 | CARD BANK 16 |
+—————+———————————————+—————+———————————————+

System Common Message

This message is transmitted when the “MIDI Sync Mode” of the system parameter
“SYSTEM/UTILITY/MIDI” is set at “INT/AUTO/REMOTE”.

Song Position Pointer

In Song mode, the current location is transmitted as a Song Position Pointer message when
the song is stopped.

Status

Second

Third

F2H

mmH

nnH

nn, mm = Song Position Point: 00H 00H - 7FH 7FH

Song Select

Transmitted in one of the following operations:
When the Song mode has been selected.
When the song has been selected in the Song mode.

Status

Second

F3H

ssH

ss = Song Number: 00H-13H (0-19)

System Realtime Message

This message is transmitted when the “MIDI Sync Mode” of the system parameter
“SYSTEM/UTILITY/MIDI” is set at “INT/AUTO/REMOTE”.

Timing Clock

Status
F8H

Start

Status
FAH

Continue

Status
FBH

Stop

Status
FCH

Active Sensing

Status
FEH
*

Always transmitted at intervals of approximately 250 ms.

System Exclusive Message

Status

Data Bytes

Status

F0H

iiH, ddH, ..., eeH

F7H

Byte

Description

F0H

Status of System Exclusive Message

ddH

Data: 00H - 7FH (0 - 127)

:

:

eeH

Data

F7H

EOX (End of System Exclusive Message)

About Model ID

The SP-505 uses 00H 39H as a Model ID.

Universal System Exclusive Message

INQUIRY MESSAGE

Identity Reply

Status

Data Bytes

Status

F0H

7EH,10FH,06H,02H,41H,39H,01H,

F7H

00H,00H,00H,02H,00H,00H

Byte

Description

F0H

Status of System Exclusive Message

7EH

Universal System Exclusive Message Non Realtime Header

10H

Device ID

06H

General Information (sub-ID #1)

02H

Identity Reply (sub-ID #2)

41H

Manufacturer ID (Roland)

39H 01H

Device Family Code (SP-505)

00H 00H

Device family No.

00H
02H
00H 00H

Softeware Revision Level

F7H

EOX (End of System Exclusive Message)

The above Identity Reply message is transmitted when an Identity Request is received.

Advertising