Problems with a memory card, Problems with midi or synchronization – Boss Audio Systems SP-505 User Manual

Page 77

Advertising
background image

77

Chapter 15. Appendices

6

Appendices

Problems with a memory card

Data was not saved correctly in a
memory card

It is possible that the power was turned off while data
was being written into the memory card (while the
“Keep Power On!” message was displayed). The lost
data cannot be recovered.

In this case, it is possible that the data of the entire
memory card has been damaged.
If you continue using the SP-505 in this state, further
malfunctions may occur. Please format the memory card.
When you format, all data in the memory card will be
lost. (p. 66)

The Protect sticker may be affixed to the memory card.

An inserted memory card is not
detected

Can’t select data from a memory
card

Is the memory card inserted correctly?

Turn off the power, remove the memory card, then re-
insert the memory card correctly.

Is the memory card an appropriate type?

The SP-505 can use 8 MB–128 MB (3.3V) SmartMedia
memory cards.
Other types cannot be used.

Is the memory card formatted correctly?

Only memory cards that have been formatted by the SP-
505 or SP-303 can be used. Please format the memory
card. (p. 66)

Problems with MIDI or synchronization

Can’t play samples from an
external MIDI device

Is the power of the external MIDI device turned on?

Are the MIDI cables connected correctly?

Check the connections.

A MIDI cable may be broken.

Is the MIDI channel set correctly?

Set the MIDI channels of the SP-505 and external MIDI
device to the same setting. (p. 71)

Is the external MIDI device set to transmit note
messages?

Make sure that the note numbers of the note messages
are in the range of note numbers that the SP-505 is able
to receive. (p. 83)

Check the settings of the external MIDI device.

Is the external MIDI device set to transmit program
change messages?

The SP-505 uses program change messages to switch pad
banks.
Make sure that the program numbers of the program
change messages are in the range of program numbers
that the SP-505 is able to receive. (p. 83)

Check the settings of the external MIDI device.

Pattern sequencer does not
synchronize to the BPM of an
external MIDI device

Is the System parameter MIDI Sync Mode set
correctly?

Check the setting. (p. 72)

Is the external MIDI device set to transmit MIDI clock
messages?

Some devices have a MIDI clock transmission on/off
setting. Also, some external rhythm machines or external
sequencers transmit MIDI clock only while they are
playing.

Is the external MIDI device set to receive MIDI clock
messages?

Check the setting of the external MIDI device.

Does the BPM of the external MIDI device exceed the
BPM range to which the SP-505 can synchronize?

The SP-505 can synchronize to a BPM in the range of
40.0–200.0. Synchronization cannot be guaranteed
outside this range of BPM.

Advertising