Service (cont.) – Bunn FMD-5 User Manual

Page 20

Advertising
background image

20

J4

J1

J2

J3

J4

J1

J2

J3

5. Reconnect the six pin connector of the wiring

harness to J3 of the control board.

6. Disconnect the four pin connector from J4 of

control board #1.

7. Check the voltage across pins 1 & 4 of the four pin

connector on the wiring harness with a voltmeter.
Connect the dispenser to the power source. The
indication must be 120 volts ac for two wire 120
volt models, three wire 120/208 volt models, three
wire 120/240 volt models.

8. Disconnect the dispenser from the power source.

If voltage is present as described, proceed to step 9.
If voltage is not present as described, refer to the
wiring diagram and check the dispenser wiring har-
ness.

9. Reconnect the four pin connector of the wiring

harness to J4 of control board #1.

10. Disconnect the ten pin connector from J2 of

control board #1.

11. Carefully connect a piece of insulated jumper wire

to pin 10 (top right) of J2 on the control board.
Keep the other end of this wire away from any
metal surfaces of the dispenser.

12. Check the voltage across the terminals of the inlet

solenoid valve with a voltmeter. Connect the dis-
penser to the power source. The indication must
be 120 volts ac for two wire 120 volt models, three
wire 120/208 volt models, three wire 120/240 volt
models after a delay of approximately 10 seconds.

13. Touch the free end of the jumper wire to the

dispenser housing. The indication must be 0.

14. Move the jumper wire away from the housing. The

indication must, again, be 120 volts ac for two wire
120 volt models, three wire 120/208 volt models,
three wire 120/240 volt models after a delay of
approximately 5 seconds.

15. Disconnect the dispenser from the power source

and remove the jumper wire.

If voltage is present as described, proceed to step 16.
If the voltage is not present as described, replace
control board #1.

SERVICE (cont.)

CONTROL BOARD

FIG. 11 CONTROL BOARD

Location:

The Control Boards are located behind the lower

front access cover mounted on the component bracket.

Test Procedure:
Liquid Level Control Circuitry(Control Board #1):
1. Disconnect the dispenser from the power source.
2. Disconnect the six pin connector from J3 of the

control board.

3. Check the voltage across pins 5 & 6 of the six pin

connector on the wiring harness with a voltmeter.
Connect the dispenser to the power source. The
indication must be 24 volts ac.

4. Disconnect the dispenser from the power source.

If voltage is present as described, proceed to step 5.
If voltage is not present as described, refer to the
wiring diagram and check the dispenser wiring har-
ness.

P2635

#1

#2

35135 012103

Advertising