Bunn FMD-5 User Manual

Page 9

Advertising
background image

9

TROUBLESHOOTING (cont.)

PROBLEM
Product will not dispense (cont.)

Water is not hot

PROBABLE CAUSE
5. Solenoid Valve (Inlet)

6. Control Board #1 and Probe

7. Auger Drive

8. Water Strainer

9. Lime build-up
CAUTION - Tank and tank compo-
nents should be delimed regularly
depending on local water conditions.
Excessive mineral build-up on stain-
less steel surfaces can initiate corro-
sive reactions resulting in serious
leaks.

10. Transformer

1. Limit Thermostat
CAUTION - Do not eliminate or by-
pass limit thermostat. Use only BOM
replacement part #29329.1000

2. Control Thermostat

3. Tank Heater

REMEDY
Refer to

Service

- Solenoid Valve

(Inlet) for testing procedures. See
page 37

Refer to

Service

- Control Board and

Probe for testing procedures. See
page 20

Refer to

Service

- Auger Drive. See

page 13 & 15

Remove the strainer and check for
obstructions. Clear or replace.

Inspect the tank assembly for exces-
sive lime deposits. Delime as re-
quired.

Refer to

Service

- Transformer for

testing procedures. See page 41

Refer to

Service

- Limit Thermostat

for testing procedures. See page 31

Refer to

Service

- Control Thermo-

stat for testing procedures. See page
19

Refer to

Service

- Tank Heater for

testing procedures. See page 38

35135 012103