FIG. 34 INLET SOLENOID VALVE TERMINALS

SERVICE (cont.)

WHI from Main Harness

7. Disconnect the dispenser from the power source.

If the sound is heard as described and water will not
pass through the solenoid valve, there may be a
blockage in the water line before the solenoid valve or,
the solenoid valve may require inspection for wear,
and removal of waterborne particles.
If the sound is not heard as described, replace the
solenoid valve.

Removal and Replacement:
1. Remove the white and violet wires from the sole-

noid valve.

2. Turn-off the water supply to the dispenser.
3. Disconnect the water lines to and from the sole-

noid valve.

4. Remove the two #8-32 screws securing the sole-

noid to the rear of the dispenser housing. Remove
solenoid.

5. Remove the two #8-32 U-Type fasteners from the

solenoid bracket.

6. Install the two #8-32 U-Type fasteners and the two

#8-32 screws on the new solenoid.

7. Install new solenoid on rear of dispenser housing

and tighten the two screws

8. Securely fasten the water lines to and from the

solenoid valve.

9. Refer to Fig. 34 and reconnect the wires.

VIO from Main Harness

SOLENOID VALVE (INLET)

FIG. 33 INLET SOLENOID VALVE

Location:

The inlet solenoid is located on the lower left side

near the rear panel.

Test Procedures:
1. Disconnect the dispenser from the power source.
2. Disconnect the white and violet wires from the

solenoid valve.

3. Check the voltage across the white and violet wires

with a voltmeter. Connect the dispenser to the
power source. The indication must be 120 volts ac
for two wire 120 volt models, three wire 120/208
and 120/240 volt models.

4. Disconnect the dispenser from the power source,

If voltage is present as described, proceed to #5
If voltage is not present as described, refer to the
wiring diagram and check dispenser wiring harness.

5. Check for continuity across the solenoid valve coil

terminals.

If continuity is present as described, reconnect the
white and violet wires to the solenoid.
If continuity is not present as described, replace the
solenoid valve.

P2635

6. Check the solenoid valve for coil action. Connect

the dispenser to the power source. Listen carefully
in the vicinity of the solenoid valve for a "clicking"
sound as the coil magnet attracts.