Using the i94xx mounting bracket – ClearCube I/Port Users Guide User Manual

Page 22

Advertising
background image

12 •

Using the I94xx Mounting Bracket

Use the I94xx mounting bracket, included with I9420 and I9440 I/Ports, to mount an I94xx
I/Port under a desk. Use the following tools to mount the bracket:

Phillips screwdriver

Optionally, a drill to drill 3/32–inch pilot holes for the mounting bracket screws.

Note:

ClearCube recommends attaching all cables to the I/Port, as described in "

Setting up

the I/Port

" on page 9, before inserting the I/Port into the bracket.

1. Use the four holes in the top of the bracket as a pattern to mark the surface (for example,

the underside of a desk) where you will attach the bracket. Ensure that:

There is a minimum of 1 ½ inches of clearance on each side of the I/Port.

There is a minimum of ¾–inch clearance above the I/Port.

The bracket is inset a minimum of 2 inches from the front of the desk.

2.

Optionally, use a drill to make 3/32–inch pilot holes in each of the bracket markings you just made.

3. Use the included wood screws to screw the bracket into the four holes. Ensure that you do

not overtighten the screws.

4. Align the grooves on the side of the I/Port with the bracket flanges and gently slide the

I/Port into the bracket until it snaps into place.

Note:

To prevent overheating, do not stand the I/Port on either of its sides, and do not cover
any ventilation holes.

Configuring the Sentral Console for the I/Port Connection

In its default configuration, Sentral automatically detects I/Ports when they are connected to a
Sentral-managed network, but some additional configuration is required. To configure the
Sentral console for your I/Port connection, do the following:

1. If using I8330 I/Ports, install the I8330 admin utility on the host where Sentral console is

installed. The I8330 admin utility is located on the Sentral installation CD.

2. From the Sentral console, run a discovery to discover all thin clients (as described in

Sentral Administrator’s Guide). From the Setup > Configuration screen, ensure that the
Discovery Update Config drop-down menu is set to True. This setting pushes out
credentials for the Primary and Secondary Sentral servers to I/Ports (however, not to
I83xx I/Ports). If Discovery Update Config is set to False, right-click the thin client
(I/Port) icon in the Hierarchical view, and select Configure to manually specify the
Primary and Secondary servers.

3. From Sentral, add the I/Port to a Thin Client Group. See Sentral Administrator’s Guide for

more information about adding thin clients to thin client groups.

4. Allocate the Thin Client Group to a host, a host group, or a virtual machine. From the

Sentral main menu, click Connection Brokering > Allocation. The Connection
Brokering - Mappings screen is displayed.

For more information, see Sentral Administrator’s Guide.