Parameters used for the data format

The following 2 types of parameters are used for command and response data:
(1) ON/OFF (2) Special Parameter
Each parameter is as follows:

(1) ON/OFF

Shows the status (ON or OFF) of the unit, such as POWER and HIDE.

(2) Special parameters

Operation mode parameters

DHCP client parameters

IP address parameters

Display the IP address using the dot (“.” (2HE)) delimiter.

Example: “192.168.0.10”

External control command table

NOTE:

● After configuring the ADHCP ClientB and AIP AddressB, execute ANetwork RestartB.

Character

Hex

Meaning

0

30

OFF

1

31

ON

Character

Hex

Meaning

0000

30 30 30 30

Standby state

0001

30 30 30 31

Power ON state

0002

30 30 30 32

Cooling state

0003

30 30 30 33

Emergency cooling state

0004

30 30 30 34

Emergency state

Character

Hex

Meaning

0

30

DHCP

1

31

Static IP

Function

Command

Setting

Asking

Data Type

Power On

ELSE

Power On

ELSE

ON/OFF

Special Parameter

Power

U0F

3(OFF)

3(ON)

-

-

3

-

Hide

U00

3

-

3

-

3

-

Operation Mode

UA0

-

-

3

3

-

Standby...

DHCP Client

UD2

3

3

3

3

-

DHCP...

IP Address

UD3

3

3

3

3

-

192.168. ...

Network Restart

UDC

3

3

3

3

-

[0] Fixed