FI22FP Low-Profile Inline Plastic Fiber Optic Sensor

Banner Engineering Corp.

Minneapolis, MN U.S.A.

www.bannerengineering.com • Tel: 763.544.3164

FI22FP Low-Profile Inline Plastic Fiber Optic Sensor

Overview

The FI22FP is an easy-to-use, low-profile fiber optic sensor. It provides high-performance

sensing in low-contrast applications and its small size lets it mount almost anywhere.

Configuration options include SETUP mode plus static, dynamic and single-point TEACH-

mode programming, in addition to manual fine adjustment, remote programming and

security lockout options.
The sensor has bipolar outputs, one each NPN and PNP.
The sensor’s compact housing has a large, easy-to-see bargraph display plus bright LEDs

for easy programming and status monitoring during operation. The sensor quickly snap-

mounts to its custom bracket (included with sensor).

Sensor Programming

Sensor configuration is accomplished through TEACH-mode programming and SETUP

mode. After TEACH mode has defined the sensing parameters, SETUP mode may be used

to enable the delay or to change the light/dark operate status. Manual Adjust may be used

to fine-tune the thresholds (see page 9). Two push buttons, Dynamic (+) and Static (-), or

the remote wire, may be used to access and set programming parameters.
Sensor programming may be accomplished using any of three TEACH methods. A single

switching threshold may be programmed using either dynamic (on-the-fly) or static TEACH.

In addition, single-point static TEACH may be used to define a sensing window, centered on

a single taught condition. Single-point TEACH can be accomplished only statically.

Remote Programming

The Remote Programming function may be used to program the sensor remotely or to

disable the push buttons for security. Connect the gray wire of the sensor to ground (0V

dc), with a remote programming switch connected between them. Pulse the remote line

according to the diagrams in the programming procedures. The length of the individual

programming pulses is equal to the value T:

0.04 seconds

T 0.8 seconds

Returning to RUN Mode

TEACH and SETUP modes each may be exited either after the 60-second time-out, or by

exiting the process:
• In static TEACH mode, press and hold the Static (-) button (or hold the remote line) for 2

seconds. The sensor returns to RUN mode without saving any new settings.

• In SETUP mode, press and hold both the Static (-) and Dynamic (+) buttons (or hold

the remote line) for 2 seconds. The sensor returns to RUN mode and saves the current

setting.

Green

Power ON

Indicator

Yellow Output

Conducting

Indicator

Programming

Push Buttons

Bargraph

Display

Delay

Dark Operate

Light

SETUP Status

Indicators:

Figure 1. FI22FP features

Fiber Ports

Switching

Point