Single-point static teach (sensing window), Single-point teach and manual adjust – Banner FI22 Expert Series User Manual

Page 6

Advertising
background image

FI22FP Low-Profile Inline Plastic Fiber Optic Sensor

6

P/N 108899 rev. C

Banner Engineering Corp.

Minneapolis, MN U.S.A.

www.bannerengineering.com • Tel: 763.544.3164

Figure 4. Single-Point TEACH (Light

Operate shown)

Sensor positions

threshold midway

between taught conditions

Sensor positions

threshold midway

between taught conditions

Darkest

(no signal)

Darkest

(no signal)

Most Light

(saturated

signal)

Most Light

(saturated

signal)

Single

taught

point

Sensing window size

adjusted by

Manual Adjust

Output OFF

Output OFF

Output OFF

Output ON

Output ON

Darkest Taught

Condition

Lightest Taught

Condition

Position

adjusted by

Manual Adjust

Darkest

(no signal)

Most Light

(saturated

signal)

Output OFF

Output ON

2nd Taught

Condition

1st Taught

Condition

Position

adjusted by

Manual Adjust

Single-Point Static TEACH (Sensing Window)

• Sets a single ON condition
• All other conditions (lighter or darker) result in OFF output
• Sensing window size (sensitivity) is adjustable using “+” and “-” buttons

(Manual Adjust)

Single-Point TEACH is most useful when a product may not always appear in the same

place, or when other signals may appear. Single-point TEACH programs a sensing window,

with the Output ON condition inside the window, and the Output OFF conditions outside the

window (see Figure 4). Output ON and OFF conditions can be reversed by changing Light/

Dark Operate status in SETUP mode.
Single-Point TEACH programming may be accomplished only using Static TEACH. The

sensor learns a single sensing condition, and adds switching thresholds above and below

the taught condition to create a sensing window.

Single-Point TEACH and Manual Adjust

Using Manual Adjust with Single-Point TEACH expands or contracts the size of the window.

The lighted LEDs on the light bar separate to a greater or lesser extent to exhibit the relative

sensing window size.

Push Button

0.04 sec.

“click” 0.8 sec.

Remote Line

0.04 sec.

T 0.8 sec.

Result

Access

TEACH

Mode

• Press and Hold

> 2 seconds

• Present Output ON

condition

• Single-pulse remote line

Power LED: OFF

Output LED: ON (Push Button)

Output LED: OFF (Remote)

Static LEDs: #2 & 3 alternately flashing

Learn

Set

Point

(Output

ON)

Condition

• Present Output ON

conditions

• Double-click push button

• Double-pulse

remote line

Teach Accepted

Power LED: ON

Bargraph: 2 indicators flash together to

show single-point Teach accepted

Sensor returns to Run mode with

new settings

Teach Unacceptable

Power LED: OFF

Bargraph: #1, 3, 5, 7 flash to show failure

Sensor returns to “Teach 1st Condition”

T

T T T

T

T

T

T

T

T

T

T

T

T

T

T

T T T

T

T

T

T

T

T

T

T

T

T

T

Advertising