FI22FP Low-Profile Inline Plastic Fiber Optic Sensor

4

P/N 108899 rev. C

Banner Engineering Corp.

Minneapolis, MN U.S.A.

www.bannerengineering.com • Tel: 763.544.3164

Sensor positions

threshold midway

between taught conditions

Sensor positions

threshold midway

between taught conditions

Darkest

(no signal)

Darkest

(no signal)

Most Light

(saturated

signal)

Most Light

(saturated

signal)

Single

taught

point

Sensing window size

adjusted by

Manual Adjust

Output OFF

Output OFF

Output OFF

Output ON

Output ON

Darkest Taught

Condition

Lightest Taught

Condition

Position

adjusted by

Manual Adjust

Darkest

(no signal)

Most Light

(saturated

signal)

Output OFF

Output ON

2nd Taught

Condition

1st Taught

Condition

Position

adjusted by

Manual Adjust

Figure 2. Two-Point TEACH (Light Operate

shown)

Two-Point Static TEACH (Switch Point)

• Sets a single switching threshold

• Threshold position is adjustable using “+” and “-” buttons (Manual Adjust)
Two-Point TEACH is the traditional setup method, used when two conditions can be

presented by the user. The sensor locates a single sensing threshold (the switch point)

midway between the two taught conditions, with the Output ON condition on one side, and

the Output OFF condition on the other (see Figure 2).
The first condition taught is the ON condition. The Output ON and OFF conditions can be

reversed by changing Light/Dark Operate status in SETUP mode.

Two-Point TEACH and Manual Adjust

Using Manual Adjust with Two-Point TEACH moves the switching threshold. The lighted

LED on the bargraph will move to exhibit the relative amount of received signal.

Push Button

0.04 sec.

“click” 0.8 sec.

Remote Line

0.04 sec.

T 0.8 sec.

Result

Access

TEACH

Mode

• Press and Hold

> 2 seconds

No action required;

sensor is ready for 1st

TEACH condition.

Power LED: OFF

Output LED: ON

Status LEDs: #2 & 3 Alternately flashing

Learn

Output

ON

Condition

• Present Output ON

condition

• Click push button

• Present Output ON

condition

• Single-pulse remote line

Power LED: OFF

Output LED: OFF

Status LEDs: #2 & 3 Alternately flashing

Learn

Output

OFF

Condition

• Present Output OFF

condition

• Click push button

• Present Output OFF

condition

• Single-pulse remote line

Teach Accepted

Power LED: ON

Bargraph: One LED flashes to show

relative contrast (good signal

difference shown; see table above)

Sensor returns to Run mode

Teach Unacceptable

Power LED: OFF

Bargraph: #1, 3, 5, 7 Alternately flash

to show failure

Sensor returns to “Learn Output ON”

condition

Bargraph

LED

Following

TEACH

Relative Signal Difference/

Recommendation

6 to 8

Excellent: Very stable operation

4 to 5

Good: Minor sensing variables

will not affect sensing reliability.

2 to 3

Low: Minor sensing variables

may affect sensing reliability.

1

Unreliable: Consider an

alternate sensing scheme.