2 . setting the output state on/off (21h), 3 . setting the maximum output voltage (22h), 4 . setting the output voltage (23h) – B&K 1787B User Manual

Page 21

Advertising
background image

21

3

rd

byte

Command ( 20H)

4

th

byte

Operation mode(0 represent front panel operation mode, 1
represent remote operation mode)

5

th

to 25

th

byte

System reserve

26

th

byte

Check sum







2. Setting the output state ON/OFF (21H)

1

st

byte

Start bit (AAH )

2

nd

byte

Address(0~0XFE)

3

rd

byte

Command (21H)

4

th

byte

Output state(0 is OFF, 1 is ON)

5

th

to 25

th

byte

System reserve

26

th

byte

Check sum



3. Setting the maximum output voltage (22H)

1

st

byte

Start bit (AAH )

2

nd

byte

Address(0~0XFE)

3

rd

byte

Command (21H)

4

th

byte

The lowest byte of voltage upper limit

5

th

byte

The lower byte of voltage upper limit

6

th

byte

The higher byte of voltage upper limit

7

th

byte

The highest byte of voltage upper limit

8

th

to 25

th

byte

System reserve

26

th

byte

Check sum









4. Setting the output voltage (23H)

1

st

byte

Start bit ( AAH )

2

nd

byte

Address(0~0XFE)

3

rd

byte

Command( 23H)

4

th

byte

The byte 0 of output voltage value

5

th

byte

The byte 1 of output voltage value

6

th

byte

The higher byte of output voltage value

Note:

We use 4 bytes of Hex number to represent a maximum voltage value. For
example the maximum voltage is 16.000V, the hex code of 16.000 is
0X00003EB0, so the 4

th

byte is 0XB0, 5

th

bye is 0X3E, 6

th

byte is 0X00, 7

th

byte

is 0X00.

Note: You can not control the power supply from the front panel when

the power supply is in calibration mode.

Advertising
This manual is related to the following products: