Bock Water heaters 32E User Manual

Page 2

Advertising
background image

– 2 –

THIS MANUAL HAS BEEN PREPARED TO ACQUAINT YOU WITH THE INSTAL-

LATION, OPERATION, AND MAINTENANCE OF YOUR WATER HEATER AND

TO PROVIDE IMPORTANT SAFETY INFORMATION.

Read all instructions thoroughly before attempting installation or operation of the

water heater. Keep these and all component instructions for future reference.

The manufacturer of this water heater will not be liable for any damages caused

by failure to comply with the installation and operating instructions outlined on the

following pages. These instructions are a guide for the correct installation of the

water heater.

If the installer lacks the necessary skills or has difficulty following the

directions, do not proceed but get help from a qualified person for that part of the

installation that is not understood.

Local plumbing and electrical codes must be followed in the installation of this

water heater. In the absence of a local code use the UNIFORM PLUMBING

CODE and the NFPA Code. Local codes may supersede instructions in this instal-

lation manual.

When two or more burners are used, each unit should have a separate

supply line to the fuel pump to prevent nuisance lockouts caused by one or both

pumps starving for oil. If this is not possible, the use of a priority

control is recommended.

Check new equipment to see if all components are in good condition.

The water heater and oil burner may be shipped as separate units. The aquastat

and immersion well may be packed with the oil burner.

The new water heater requires fuel (#I or #2 heating oil), electricity and should be

close to the chimney and water supply. Locate the heater near a floor drain if pos-

sible for easy maintenance and protection if trouble should occur. Allow ample

space around the heater for servicing (see combustible clearance warning, page

1). Adequate air for combustion must be available. NOTE: Locate the heater so it

is not subject to physical damage by moving vehicles or possible flooding.

CONSUMER

RESPONSIBILITIES

MULTIPLE BURNER

INSTALLATION

SELECT THE RIGHT

LOCATION

FIGURE 1

Check for exhaust fans in

the heater room or adja-

cent areas which draw

combustion air away from

heater.

THE HEATER

MUST HAVE COMBUS-

TION AIR TO OPERATE.

WHEN THE WATER HEATER IS USED IN A COM-

BINED APPLIANCE APPLICATION, PLEASE

CONTACT THE LOCAL DISTRIBUTOR OR THE FAC-

TORY FOR INSTALLATION INSTRUCTIONS ON

“SYSTEM PLUS”.

DO NOT INSTALL THE WATER HEATER ON COMBUS-

TIBLE FLOORING (see Figure 2). Refer to NFPA 31 or

contact Bock Water Heaters with questions concern-

ing proper flooring materials.
Minimum clearance to combustible construction is:

SIDES 6"; BACK 6"; FRONT 24". The installation of

this water heater must conform with local codes and

ordinances. In the absence of local codes, the instal-

lation must comply with the National Fire Protection

Association (NFPA 31) Code.

FAILURE TO FOLLOW

THESE INSTRUCTIONS

OR ALL APPLICABLE

BUILDING CODES AND

REGULATIONS VOIDS

THE WARRANTY ON THIS

WATER HEATER.

Advertising
This manual is related to the following products: