INSTALLATION

Check the appliance is electrically safe and gas sound when you have finished.

27

3-Wire Conduit Installation

Disconnect the supplied power cord from the terminal block

and ground post. Keep the terminal block parts; you will need

them. Remove the strain relief clamp from the power cord

and remove the power cord and strain relief clamp from the

mounting bracket.
The range is shipped with reducer plates to give a 1

1

/

8

’’

(2.9 cm) diameter opening for conduit connection. Find the

reducer plates (Fig.6-26) in the conversion kit and fix them to

the mounting bracket.
Install a squeeze connector (not supplied with the range), to

your conduit. Insert the conduit through the reducer plates

on the mounting bracket. Allow enough slack to easily attach

the wires to the terminal block (Fig.6-27).
Note: Do not install the conduit without a squeeze connector.
Attach the ground strap to the ground and center terminal of

the connector block (Fig.6-28).
The neutral or ground wire of the power cord must be

connected to the neutral terminal located in the center of the

connector block. The power leads must be connected to the

outside terminals.
Note: Make sure the wires are completely inserted into the

terminals and secure connections are made.
Secure the squeeze connector in place in the bracket by

tightening the squeeze connector screws.

ArtNo.280-0039 Reducer Plate

ArtNo.280-0043 3-Wire conduit fitting

Fig.6-26

Fig.6-27

ArtNo.280-0083 - 3-Wire conduit connection

Black

White

Red

‘Ground strap’
(grey)

Ground

Fig.6-28