5 parts list, 6 clean-up – Trebor 50R-X12 Maxim User Manual

Page 15

Advertising
background image

MAXIM 50R PUMP OPERATION / MAINTENANCE MANUAL

PAGE 15

4.5 PARTS LIST

ILL
NO

PART NO

QTY

DESCRIPTION

PM

YEAR #

MATERIAL

1

AM075

1

Damper Plug

PTFE

2

AM084

1

Surge Port Seal

PTFE

3

AK192

1

Body

PTFE

4

98003079

2

Shaft Seal

2

PTFE

5

AK004

1

Shaft

2

PFA

6

1700B0041

2

Push Plate

PTFE

7

1700C0047

4

Diaphragm

2

PTFE

8

W0151

2

Fiber Optic Target

2

PTFE

9

AK124

2

Head

PTFE

10

AK018

2

Pilot Seat

1 & 2

PFA, PTFE

11

AK030

2

Pilot Cap Seal

PTFE

12

AK008

2

Pilot Cap

PTFE

13

AK003-01

2

Union Nut

PVDF

(PP optional)

14

AM035

2

Leak Port Plug

PTFE

15

AM037

2

Leak Port Seal

PTFE

16

AK182

4

Transfer Tube

PFA

17

98003277

4

Transfer Tube Nut

PP

18

AK076

1

Control Base

PP

19

AK088

1

Mounting Base

PP

20

AK108

1

Locking Lever

PP

21

98003071

3

Screw, PP

PP

22

98003080

2

1/4 NPT Fitting

PP

23

L0104

1

Detent Cap

PP

24

L0113

1

Detent Cap Seal

PTFE

25

L0131

1

Spool Assembly, High Load

Ceramic,

PEEK, Delrin

25a

L0197

2

Detent Leg

1 & 2

Torlon

25b

L0145

1

Detent Ring

1 & 2

PEEK

26

L0105

1

Detent Adapter

PP

27

AK058

1

Shuttle Sleeve Assembly

Ceramic,

PTFE

28

AK205

1

Muffler Assembly

1 & 2

PP

29

AK149

2

Suction Plug

PTFE

30

AK153

2

Check Port Seal

2

PTFE

31

AK066

2

Suction Seat

PTFE

32

98002334

4

O-Ring

2

PTFE

33

98001415

4

Check Ball

2

PTFE

34

AK068

2

Suction Check

PTFE

35

AK026

2

Discharge Check Cage

PTFE

4.6 CLEAN-UP

To help remove potentially dangerous chemicals prior to service or shipment, the
pump should be flushed with DI water or disassembled and thoroughly cleaned.
Allow DI water to flush through the inlet and out the outlet to prevent pressure
build up.

CAUTION: When handling pump wear appropriate personal protection

gear, including safety glasses.

Advertising