MAXIM 50R-X12 PUMP OPERATION / MAINTENANCE MANUAL

4.7 DISASSEMBLY

During the life of the pump it will be necessary to perform certain preventative
maintenance procedures to ensure its continued high performance. This section
and the next (4.8

Assembly) are provided for the user’s convenience in

disassembly and re-assembly procedures.

Loosen quick grip nuts on the transfer tubes from the pump base using

13/16” open-end wrench.

Remove pump assembly from the pump control base.

Immerse or flush the pump assembly using DI water and a neutralizing agent.

Install pump into tie down fixture with the fluid ports away from the mounting

fittings and tighten the clamp nuts. Lock the body into bench mounting
fixture. NOTE: Securely attach mounting fixture to work surface using
hardware provided.

Figure 4-1

Remove the transfer tubes from pump heads (using latex gloves).

Using strap wrench, turn union nuts counter-clockwise to remove.

Figure 4-2