MAXIM 50R PUMP OPERATION / MAINTENANCE MANUAL

PAGE 3

1

INSTALLATION

1.1 UNPACKING

After unpacking, the pump should be checked for any damage that may have
occurred during shipment. Damage should be reported to the carrier
immediately.

The following items should be included within the shipping container:

Qty

Item

Description

1

M50R-X12

Maxim 50R-X12 Pump

1

MM50R-X12

Operation/Maintenance Manual

1.2 UTILITIES / HOOK-UP

It is recommended that the pump be positioned within 15

from level to maintain

self-priming ability and pumping efficiency. Allow sufficient room for tubing
connectors. The pump mounts on a quick-change base for easy installation.

The pump has an exhaust location on the backside of the base. The exhaust
location requires 1/2” (12mm) minimum clearance behind the control base. Care
should be taken to elevate the pump whenever possible to help prevent flooding
these ports when the pump is located in a wet bench plenum. For remote
exhaust connection see Section 1.3.

Air Inlet:

1/4” FNPT (3/8” Dia. [8mm] supply tube minimum).

Fluid Ports: Integrated

male ¾” Super 300 Type Pillar

®

fluid ports Surge

Suppressor requires torqueing during pump installation. See
Section 2 for hook- up diagram and torque values..

Air Supply:

20-60 psig (.14

– .41 MPa) clean dry air or nitrogen (See

Performance Charts, Section 3.1.)