Install chains, Install valves, Install selector valve – Great Plains 3S-5000HDF Assembly Instructions User Manual

Page 8: Configure selector valve

Advertising
background image

8

Great Plains Manufacturing, Inc.

Front Page

Appendix

3S-5000/F/HD/HDF Markers

113-890M

Front Page

Appendix

2013-04-09

Install Chains

Refer to Figure 12
35. Select one new:

113-898D CHAIN 1/4 COIL HI TEST 115 IN

and one each:

802-099C HHCS 1/2-13X3 1/4 GR5

and one:

803-019C NUT LOCK 1/2-13 PLT

Connect the final link on one end of the chain

to

the center plates of the lift arm

, using the

bolt

and lock nut

.

Note: It may be necessary to raise and support the third

marker section to complete the next step.

36. Select one each:

802-041C HHCS 1/2-13X3 1/2 GR5

803-019C NUT LOCK 1/2-13 PLT

Connect the final link on the other end of the
chain

to the inboard end of the level link

tube

, using the bolt

and lock nut

.

Install Valves

See page 22 for hydraulic fitting torque values.

Install Selector Valve

Configure Selector Valve

Refer to Figure 13 (when installed, the handle is on top {Up}
and the center {EL} ports will be to the Left)
37. Select one new:

810-274C DOUBLE SELECTOR VALVE 3/4FORB

and two new:

811-171C EL 3/4MORB 9/16MJIC

Install the two elbows

in the center ports, with

MJIC ends oriented toward what will be the Front
when the valve is installed on the tongue.

129

U

D

F

B

O

I

115

134

158

147

158

144

Figure 12

LH Chain

34773

129

147

158

129

134

147

158

144

158

129

115

144

158

4

183

189

L

R

F

B

D

U

Figure 13

Selector Valve Fittings

34782

183

189

189

Advertising