Troubleshooting – BE Pressure supply 30 Gallon Diesel Compressor / Welder / Generator AC1030K5000W User Manual

Page 6

Advertising
background image

6

Problem

Possible Cause

Solutions

Excessive oil

discharge in

air (All

Compressors

have a small

amount of oil

carry over in

compression)

1. Worn piston rings or cylinder.

2. Restricted air intake.

3. Oil level to high.

4. Compressor has exceeded it

duty cycle.

1. Clean or replace air filters.

2. Reduce oil level to

recommended amount.

3. Reduce compressor duty cycle

(repair leaks or add another unit

to handle the excess demand).

Compressor

Overheating

1. Poor ventilation.

2. Dirty cooling surfaces.

3. Compressor is out of its

operating duty cycle.

1. Relocate compressor to any

area with better ventilation (at

least 18 inches from the nearest

wall).

2. Clean all cooling surfaces.

3. Reduce compressor duty cycle

(repair leaks or add another unit

to handle the excess demand).

Excessive belt

wear

1. Pulley out of alignment.

2. Improper belt tension.

3. Pulley damaged of loose.

1. Realign pulley with flywheel.

2. Readjust belt tension.

Compressor

won’t start in

cold

weather

1. Bad check valve.

2. Compressor has wrong grade

oil.

3. Control lines frozen.

1. Use IS 100 (30W) compressor

oil for cold weather conditions.

2. Move compressor to a warmer

location.

3. Put a heat lamp on compressor

to maintain above freezing

temperatures.

Compressor

has excessive

vibration

1. Compressor is not properly

mounted on vibration isolation

pads.

2. Compressor pulley is out of

alignment.

3. Engine is low on fuel of throttle

is out of adjustment.

1. Properly mount compressor on

vibration isolation pads.

2. Re-align pulleys.

3. Check drive engine oil and fuel

level.

4. Re-adjust engine throttle control

(bull whip).

troubleshooting

Advertising