Every 3 months:

Change oil to ensure that the compressor has proper oil level and that

the oil in the machine does not deteriorate past factory specifications.
Inspect valve assemblies to prevent premature failure and clean out and

carbon that can form in older valves.
*Elite units clean auto tank drain strainer and check for proper function.
Inspect pressure switch for proper function.
Inspect check valve for proper function and remove any carbon

accumulation to prevent premature failure.
*Clean belt guard coolers (if equipped).

Storage of Compressor:

Before storing the compressor for a prolonged period of time, use a blow

gun to clean all debris from compressor. Shut OFF main power and turn

OFF disconnect. Drain tank pressure, clean air filter, drain old oil and

replace with new oil. Cover the unit to prevent dust and moisture from

collecting on the unit.