CTEK Z4200U SkyRouter User Manual

Page 24

Advertising
background image

26 October 2012

20

Figure 15 - Relay Output Configuration



Set Relay Output State – Used to set the current state of the relay driver circuit. The relay driver can be activated and
deactivated by changing this setting and pressing update.

Relay Initial Value - This pull down determines the initial state of the relay when the SkyRouter reboots or recovers from
a power failure. Choices are On, Off, or Last. Last will return the relay output to the state it was in when the power fail
occurred.

Relay Shut Off Timer – The relay driver circuit will revert to its default setting after the number of minutes or seconds
specified by this parameter. The two second setting is useful for resetting end point equipment.

Allow SMS Control of Relay – If Yes is checked the relay driver may be activated by sending an SMS with the command
“R1” and deactivated by sending an SMS with the command of “R0”.

Allow Web Browser Control of Relay – If set to yes a button will appear on the Advertising screen to enable and disable
the relay driver circuit.

Text For Web Link To Relay – This text will appear on the advertising screen next to the relay activation button.

4.3 Status

4.3.1 Wireless

Status


The Wireless Status interface provides information on the Z Series router’s wireless network connection, local operating
conditions, and predefined information contained within the radio module. Wireless status information is presented in two
levels of detail, summary and detailed. Either level can be refreshed (updated) in real time using the Refresh button at the
bottom of the page. The Wireless Status interface is display only. This manual section explains both the Z4200 (CDMA)
Wireless Status screen and the Z4400 (HSPA) screen as they are different.