Maintenance & Care

machine storage

Put unit away in a closet or basement for next

use. store cleaner in a protected, dry area. since

this product uses water, it must not be stored

where there is a danger of freezing. Freezing will

damage internal components and void guarantee.

fluid connection point filter maintenance

Periodic cleaning of fluid connection point

filters in spray nozzle may be required.
1. To clean fluid connection point filters,

remove nozzle and turn it over.
2. Clean filters on ends of fluid connection

points with a small paperclip and re-attach

nozzle to machine.

Drive belt removal & replacement

Occasional replacement of one or both belts

may become necessary. if needed, please follow

instructions below.
1. Turn off machine, and unplug it from outlet.

Wrap hose and cord on racks.
2. Remove 2-in-1 water tank and set aside.
3. Remove nozzle by turning locking keys

counterclockwise to “unlock” position and

lifting nozzle up and away.
4. Turn machine on its side. Important: make

sure corded side is facing up.
5.
Remove 1 silver screw from pivot arm.
6. Remove pivot arm by gently lifting up.
7. Remove old drive belt and replace it with

a new belt by first attaching it to small drive

wheel, then attaching it to end of inside brush.
8. Place pivot arm back on and secure in place

using silver screw.
9. Replace nozzle by lining up locking keys with

their slots and placing nozzle back onto foot of

machine. secure into place by turning locking

keys clockwise to “lock” position.

1.

2.

www.bissell.com

12

1

4

6

8

2.

3.

4.

5.

6.

7.

8.

9.

WARNING

To reduce the risk of electric shock, push power button

off and disconnect plug from electrical outlet before

performing maintenance or troubleshooting checks.

Advertising
This manual is related to the following products: