Troubleshooting guide, Procedure for removing error code from faceplate – EcoPure MW_MW30_7301415A User Manual

Page 25

Advertising
background image

25

Miracle Water Installation & Operation Manual

Troubleshooting Guide

Tools Needed for Most Repairs: 5/16 Hex Driver, Phillips Screwdriver, Needle-nose Pliers

PROBLEM

CAUSE

SOLUTION

REPAIR KIT(S)

NEEDED

No Soft Water

1. No Salt in the storage tank

a. Add salt (see page 22)

b. Use Recharge Now feature (page 20)

None

No Soft Water Timer

Display Blank

1. Transformer unplugged at wall outlet, or power cable

disconnected from back of faceplate,

Transformer defective

a. Check for loss of power and correct. Reset timer

and use the Recharge Now feature (page 20)

Transformer

2. Fuse blown, circuit breaker popped, or circuit

switched off. (See page 20 “Timer Power Outage

Memory).

a. Replace fuse, reset circuit breaker, or switch circuit

and use the Recharge Now feature (page 20).

None

3. Timer control board defective

a. Replace Electronic Control Board (page 29)

Timer Control Board

No Soft Water

Salt Level Not Dropping

1. Salt in storage tank bridged

a. Refer to page 22 to break.

None

2. Manual bypass valve(s) in bypass position

a. See page 15 figure 10. Move stern in single bypass

to service

None

No Soft Water, Salt

Storage Tank Full of

Water, Water Running To

The Drain (While Unit Is

In The Soft Water Cycle)

1. Dirty, plugged or damaged nozzle & venturi

a. Take apart, clean and inspect nozzle and venturi

(see page 23)

Nozzle Kit

2. Inner valve defect causing leak

a. Replace seals and rotor (page 29)

Rotor/Seal Kit

3. Valve drain hose plugged

a. Hose must not have any kinks, sharp bends or any

water flow blockage (see page 9)

None

4. Valve drain line and Salt Storage Tank overflow drain

connected together by a tee.

a. Disconnect tee, run separate drain lines.

None

5. Low or high system water pressure (low pressure

may disrupt brine draw during recharge, high pres-

sure may cause inner valve parts failure)

a. If pressure is low, increase well pump output to a

minimum 20 psi. Add a pressure, reducing valve in

the supply pipe to the softener, if daytime pressure

is over 100 psi.

None

6. Brine valve float kit dirty or defective

a. Clean Brine or replace valve float kit assembly

(page 29)

Float Kit

7. Leak between valve and resin tank assembly

a. Replace Tank/Valve O-Rings

Tank/Valve O-ring Kit

Water Hard Sometimes

1. Time setting wrong

a. Check and change time setting

None

2. Incorrect water hardness setting

a. Refer to page 18 to find correct settings

None

3. Incorrect model code programmed

a. Refer to page 17 to find correct settings

None

4. Hot water being used when softener is regenerating

a. Avoid using hot water while the softener is regener-

ating as the water heater will fill with hard water.

Check timer for correct settings

None

5. Possible increase in water hardness

a. Test the raw water for hardness and iron and pro-

gram the time accordingly (page 17)

None

6. Leaking faucet or toilet valve. Excessive water

usage.

a. A small leak will waste hundreds of gallons of water

in a few days. Fix all leaks and always fully close

faucets.

None

Iron In Water

1. Clear water iron in water supply

2. Iron in soft water

3. Bacterial or organic bound iron

a. Test the raw water for hardness and iron and pro-

gram the time accordingly (page 17)

b. Clean resin bed with Resin Bed Cleaner

c. Cannot be treated by water softener

None

Resin In Household

Plumbing, Resin Tank

Leaking

1. Crack in distributor or riser tube

a. Replace resin tank assembly (page 29)

Resin Tank Assembly

Salt Storage Tank

Leaking

1. Crack in brine tank

a. Replace salt storage tank assembly (page 29)

Salt Storage Tank

Assembly

Motor Stalled Or Clicking

1. Motor defective or inner valve defect causing high

torque on motor

a. Replace Rotor/Seal Kit (page 29)

b. Replace Motor & Switch

Rotor/Seal Kit

Motor/Switch Kit

Error Code E1, E2, E3, or

E4 appears

1. Wiring Harness or Connection to Position Switch

2. Switch

3. Valve Defect Causing High Torque

4. Motor Inoperative

a. Replace Wiring Harness or Connection to Position

Switch

b. Replace Switch

c. Replace Rotor Seal Kit

d. Replace Motor

Motor/Switch Kit

Rotor/Seal Kit

Error Code E5 appears

1. Faceplate

a. Replace Electronic Control Board

Electronic Control Board

Kit

PROCEDURE FOR REMOVING ERROR CODE FROM FACEPLATE:

1. Unplug transformer from outlet- - - - 2. Correct defect-

- - - 3. Plug in transformer- - - - 4. Wait for 6 minutes. The error code will return if the defect was not corrected.

Need help troubleshooting? Call 1-800-356-7851

Advertising