Maintenance (continued) – HeatStream HS-215T-KFA User Manual

Page 10

Advertising
background image

NOZZLES:

Nozzles should be cleaned or replaced at least once per heating
season. Contaminated fuel could make this necessary
immediately

.

To clean dirt from nozzle, blow compressed air through nozzle
front. It may be necessary to soak nozzle in clean 1-K kerosene
to help loosen any particles.
NOTE: Use of diesel may require additional maintenance. Using
this heater without proper maintenance or with contaminated or
old fuel may lead to improper combustion and possible soot
production. BE SURE FUEL USED  IS APPROVED (see
OPERATION on page 6).

SPARK PLUG:

Clean and re-gap every 600 hours of operation, or replace as
needed.After removing the Spark Plug, clean the terminals with a
wire brush. Re-gap the terminals to 0.140” (3.5mm).

PHOTOCELL:

The Photocell should be cleaned at least once per heating
season or more depending on conditions.
Use a cotton swap dipped in water or alcohol to clean the lens of
the Photocell. Note the proper Photocell position as noted in
Figure 17 and Figure 18.

© 2012, Pinnacle Products International, Inc.

10

Kerosene User’s Manual

Maintenance (Continued)

Burner Head

Screw

Spark Plug

Ignitor Wire

Fuel Line Hose

Air Line Hose

Burner Head

Nozzle

Nozzle Face

Air Line Fitting

Fuel Line Fitting

Figure 15: Nozzle Replacement

Ignitor Wire

Burner Head

Spark Plug

Gap

Figure 16: Spark Plug Replacement

Photocell

Photocell
Lens

Installing Photocell:

1) Incorrect

2) Correct

Figure 17: Photocell Positioning

NEVER LEAVE HEATER

UNATTENDED WHILE BURN-

ING OR WHILE CONNECTED

TO A POWER SOURCE

Advertising