Maintenance (continued) – HeatStream HS-215T-KFA User Manual
Page 11
FUEL FILTER:
The Fuel Filter should be cleaned at least twice per heating
season by rinsing it in clean 1-K kerosene. Contaminated fuel
could make this necessary immediately (See Figure 19).
NOTE: To remove the filter from models HS-45 / 70T-KFA, turn
filter 90° clockwise. To remove the filter from models HS-125T /
175T / 215T-KFA, turn filter 90° counter-clockwise.
Use of diesel may require additional maintenance.
Improper
maintenance can lead to poor combustion and soot
production!
PUMP PRESSURE ADJUSTMENT:
While heater is operating, turn relief valve clockwise to increase,
counterclockwise to decrease (see Figure 20). Use flat blade
screwdriver to turn valve. Correct pump pressure is as follows:
For best measurement of pressure, test with full tank of
fuel. Optimum pressure occurs when the nose cone is
cherry red and there are no extending flames from the
heater.
© 2012, Pinnacle Products International, Inc.
11
Kerosene User’s Manual
Maintenance (Continued)
Photocell
Wire
except
HS-45-KFA
Circuit Board
Figure 18: Photocell Position in Heater
Side Cover
Screw
Power Switch
Power Switch Wire
Circuit Board
Fuel Filter
Photocell Wire
Fuel Line
Figure 19: Fuel Filter Replacement
Model #
Pump Pressure
HS-45-KFA
3.0 PSI
HS-70T-KFA
4.0 PSI
HS-125T-KFA
5.0 PSI
HS-175T-KFA
7.5 PSI
HS-215T-KFA
9.0 PSI
Tolerance ± 10%
Adjusting
Screw
Figure 20: Pump Pressure Adjustment
NEVER LEAVE HEATER
UNATTENDED WHILE BURN-
ING OR WHILE CONNECTED
TO A POWER SOURCE