FUEL FILTER:

The Fuel Filter should be cleaned at least twice per heating
season by rinsing it in clean 1-K kerosene. Contaminated fuel
could make this necessary immediately (See Figure 19).

NOTE: To remove the filter from models HS-45 / 70T-KFA, turn
filter 90° clockwise. To remove the filter from models HS-125T /
175T / 215T-KFA, turn filter 90° counter-clockwise.

Use of diesel may require additional maintenance.

Improper

maintenance can lead to poor combustion and soot
production!

PUMP PRESSURE ADJUSTMENT:

While heater is operating, turn relief valve clockwise to increase,
counterclockwise to decrease (see Figure 20). Use flat blade
screwdriver to turn valve. Correct pump pressure is as follows:

For best measurement of pressure, test with full tank of
fuel. Optimum pressure occurs when the nose cone is
cherry red and there are no extending flames from the
heater.

© 2012, Pinnacle Products International, Inc.

11

Kerosene User’s Manual

Maintenance (Continued)

Photocell
Wire

except
HS-45-KFA

Circuit Board

Figure 18: Photocell Position in Heater

Side Cover

Screw

Power Switch

Power Switch Wire

Circuit Board

Fuel Filter

Photocell Wire

Fuel Line

Figure 19: Fuel Filter Replacement

Model #

Pump Pressure

HS-45-KFA

3.0 PSI

HS-70T-KFA

4.0 PSI

HS-125T-KFA

5.0 PSI

HS-175T-KFA

7.5 PSI

HS-215T-KFA

9.0 PSI

Tolerance ± 10%

Adjusting

Screw

Figure 20: Pump Pressure Adjustment