Baumer GNAMG User Manual
Page 9
Manual_GNAMG_Profibus_EN.doc 9/19
Baumer IVO GmbH & Co. KG
04.05.11
Villingen-Schwenningen,
Germany
Parameter values of parameterization function (Set_Prm)
Parameter
Data
type
Octe
t Nr.
Value range
Default parameter
in GSD file
Station status
Octet
string
1
• Sync and freeze
mode supported
• Supported
baud
rates
Response monitoring
time
Octet
string
2 to 3
Profibus-specific
data
Minimum Station Delay
Responder
Octet
string
4
Depending on Baud
rate
Ident No.
Octet
string
5 to 6
059B
Group Ident No.
Octet
string
7
00
Operating parameter
Octet
string
8
Profibus-specific
data
Parameters of the
inclination sensor
Octet
string
9
• Bit 0 = 0/1 inversion X-axis
• Bit 1 = 0/1 inversion Y-axis
• Bit 2 = 0/1 scaling X-axis
• Bit 3 scaling Y-axis
• Bit 4 = 0/1 standard
diagnosis/ extended
diagnosis
• less inversion
• less inversion
• less scaling
• less scaling
• extended
diagnosis
Resolution
Octet
string
10
0x00 to 0x03
0x00 = 0.001° Resolution
0x01 = 0.01° Resolution
0x10 = 0.1° Resolution
0x11 = 1.0° Resolution
Default = 0x10 =
0.1°