Operators instructions cleverlevel switch, lffs, Mounting connections – Baumer CleverLevel - LFFS User Manual

Page 4

Advertising
background image

Refer to data sheet ”Accessories Universal” for further
information



NOTE:
The LFFS must be mounted in a Baumer mounting
connection. If not, Baumer do not guarantee correct
function or tightness.

Operators instructions
CleverLevel switch, LFFS

Mounting connections

ISO2852

SMS 1145

Welding

DN38: CAM023.505

DN51: SAM020.051.1

for tank

DN51: CAM023.640

PM023




Variline, type N

DIN 11851

Welding

VAM023

DN25: MAM020.025

for tank

DN40: MAM020.040

PM021

DN50: MAM020.050


Adapter

Welding

G½ → G1

to pipe end

RAM020.1

DN25...50: PM022.1

DN65...100: PM022.2


Adapter

Welding Ø35

1” level switch

for tank/tube

LAM020.3

PM025




Adapter, industrial

G½ → G1

RAM020.2

Welding

for tank

8126916




Welding

for pipe end

8126928

www.baumer.com

Operators instructions: 11109132 02 EN Page 4 / 12

On a welding adapter there is an
arrow or a 3A logo.
This must be placed upwards when
welding the adapter into a tank
(horizontal position).
This assures that the electrical con-
nection will be pointing downwards
(opposite of the arrow; 3A logo)

Advertising