Operators instructions cleverlevel switch, lffs, Manually teach-in, Using the flexprogrammer 9701 alone and teach-in – Baumer CleverLevel - LFFS User Manual

Page 6

Advertising
background image

Operators instructions
CleverLevel switch, LFFS

Teach-In using the FlexProgram and FlexProgrammer 9701

Sophisticated settings for Teach-In as well as output type, diagnostics, data logging, tag no. and damping can be configured using
the FlexProgrammer 9701. Integrated HELP-menus will give full instruction.

Press  or  to browse the menus

 to access current menu point

 to return to previous menu

 and  simultaneously to reset FlexProgrammer

and go in sleep mode


Teach-In
Press

and 

simultaneously

Select Menu “Teach-In”

Search for product

= Product LFS/LBFS

At empty tank

setting 0%

At full tank

setting 100%

Manually Teach-In

Make sure that power is on before Teach-In.
For best Teach-In it is important the product is fixed in the final application.
During Teach-In mode the light intensity of the LED will decrease, please protect your eyes.

Step

To do

LED

Result

1

Connect terminal ”Teach-In” to
- VDC (T1 or T2) for 3,5 second

Flash 1 time per second

Ready for Teach-in

2

With no media present connect
”Teach-In” to - VDC shortly

Light on for 2 second and then flash

Register ”empty” state. Pls. See note

3

With media present connect
”Teach-In” to - VDC shortly

Light on for 2 seconds

Register ”full” state, stores the value and returns to
Normal operation with new setting

NOTE:
If the media is sticky, foamy, powdery or in other ways leaving parts of the media at the sensor tip this situation has to be estab-
lished also during the Teach-In process. Otherwise a faulty calibration can be the result.

If Teach-In for some reason do not succeed, the CleverLevel Switch LFFS will enter “Error State” and automatically reload factory
settings . The factory settings can always be reloaded by connecting the terminal “Teach-In” to -VDC for more than 6.5 seconds.
A reloaded factory settings will be confirmed by pulsing light intensity 3 times.

Error state description LED

Result

Error state

Blinking, 3 × short and 1 × long Can normally be fixed by powering off and on and remake the Teach-In.

Alternatively remake the Teach-In configuration by use of the FlexPro-
gram and the FlexProgrammer 9701

Using the FlexProgrammer 9701 alone and Teach-In

FlexProgrammer 9701 stand alone menu

Press
 Turn on FlexProgrammer if in sleep mode

Empty configuration

 Search for product

LFFS/LBFS configuration

 Product

LFFS / LBFS

 TAG number

xxxxxxxxxxxxxxx

 Range min.

x.x%

 Range max.

xx.x%

 Damping

x,x sec

 Output config. Xxxxxxx
 Trigger level

xx,x%

 Range hyst.

x,xx%

 Trigger hyst.

x.xx%

www.baumer.com