5 options, P.25 – Camco Amplifier User Manual

Page 27

Advertising
background image

5 OPTIONS

ENTER-Switch

CAI LED

USER MANUAL
VORTEX 3 QUADRO

P.25

5. CAI (CAMCO Audio Interface)

CAI is a bus system, in which all significant device functions can be monitored
externally and remotely controlled using a master PC. Up to 99 devices can be
controlled in parallel in each phase of the bus system, which simply consists of
a two-core insulated cable. The master can serve several phases for larger appli-
cations. For more information, please contact your dealer or distributor.

CAI allows:

To control the output-level of each Channel independently

(exception: mono modes, only Channel A(C) is affected)

To mute each channel independently

(exception: mono modes, only Channel A(C) is affected)

To switch the VORTEX into STANDBY (and back again)
To monitor temperature, output-signal, clip, output-current.

5.. Wiring

To connect the VORTEX to your CAI system use a fully-wired telephone-type
cable with RJ2 connectors. For longer distances use high grade cable like
for RS485, DMX52 for AES/EBU digital audio. You can chain several VORTEX
amplifiers using the second CAI connector on each amplifier. A linear network
topology is recommended with 00 Ohm termination at its end. Please refer to
RS485 specifications.

5..2 CAI Address Settings

The VORTEX 3 QUADRO uses two addresses to communicate with the master
PC. You only select the address for amplifier A/B, the address of amplifier C/D is
automatically set to address for amplifier A/B plus one.
The CAI address selection procedure will not affect the operation of the
VORTEX but whilst this procedure is active, the volume cannot be adjusted by
using the pots.

Briefly press the ENTER-Switch

. This push button switch can be accessed

through the 3 mm hole in the front panel located between the On/Off switch
and the LEDs. Only operate this switch with an insulated object.

After briefly pressing the Enter-Switch

the actual address of amplifier A/B

will be displayed by the On LEDs of ChA and ChB. The address of amplifier C/D
is not shown.

Flashing of On LED channel A indicates the tens

Flashing of On LED channel B indicates the units of the address of amplifier A/B

These sequences are repeated for 30 seconds (timeout). Then the On LEDs
return to their normal function.

To change CAI addresses, turn the appropriate volume potentiometer to
the required address of amplifier A/B (Volume Pot Ch A => Tens, Volume Pot
Ch B => Units). The address of amplifier C/D is automatically set to address for
amplifier A/B plus one.